Trusted HVAC Services in Monticello, FL
For AC and heating services that go above and beyond, connect with Benson’s Heating & Air Conditioning! We have the best around in service, prices and perks such as upfront pricing and a 100% satisfaction guarantee. And best of all, you can count on us any day of the week at any time as we are available around the clock for emergencies in Monticello, FL.
Connect with us 24/7 at 850-562-3132 for fast, reliable HVAC service in Monticello, FL!
Our Heating and Air Services in Monticello, FL
Our full services include repair, replacement and maintenance on:
To learn more about our services, company and perks, please connect with us today. We invite you to also check out some of our reviews below from clients near you. They demonstrate our commitment to customer satisfaction in every job we do in the Monticello area, from the smallest fixes to the largest system overhauls.
Monticello, FL, HVAC Company FAQs
An HVAC tune-up typically includes the following in Monticello, FL:
- A cleaning of your HVAC unit
- An inspection of your HVAC unit
- A lubrication of your HVAC unit’s parts
- A replacement of your air filter
Getting your HVAC unit tuned up has many advantages because it keeps your system running smoothly and helps your energy costs stay low. To get the most out of servicing your HVAC unit, you should have it tuned up twice a year.
A home air conditioning unit recharge should cost around $350-$1,200. Some things that can impact the price of the recharge are:
- How severe the leak is
- How much refrigerant needs to be recharged
- The type of refrigerant your AC unit uses
If your leak is severe and your AC unit still uses the refrigerant R22, the cost of the repair will be on the higher end of the range. Since R22 has been discontinued, it is harder and more expensive to obtain.
To get the cleanest indoor air for your Monticello, FL home you should:
- Clean your home on a regular basis
- Open windows to let in fresh air
- Utilize exhaust fans
Another thing you can do if your indoor air quality is suffering is to get an air purifier for your home. Air purifiers can be helpful in filtering your indoor air when other methods are not as effective.
Recent Jobs and Reviews in Monticello, FL
Our Local Reviews by City
- Alligator Point, FL (30)
- Altamonte Springs, FL (1)
- Attapulgus, GA (4)
- Bainbridge, GA (12)
- Boston, GA (6)
- Bristol, FL (8)
- Cairo, FL (1)
- Cairo, GA (11)
- Carrabelle, FL (25)
- Chattahoochee, FL (12)
- Climax, GA (5)
- Crawfordville, FL (180)
- Eastpoint, FL (7)
- Greenville, FL (17)
- Havana, FL (344)
- Lamont, FL (14)
- Madison, FL (14)
- Meigs, GA (2)
- Metcalf, GA (1)
- Midway, FL (30)
- Monticello, FL (269)
- Mount Pleasant, TN (1)
- Ochlockonee Bay, FL (2)
- Panacea, FL (62)
- Panama City Beach, FL (1)
- Quincy, FL (213)
- Quincy Historic District, FL (5)
- Saint George Island, FL (6)
- Saint Teresa, FL (12)
- Seffner, FL (1)
- Sopchoppy, FL (10)
- Tallahassee, FL (11446)
- Thomasville, GA (23)
- Virgie, KY (1)
- Whigham, GA (2)
Job Locations and Reviews
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Attic - Air Handler Area Unit Services: - Front of house Filtration: - Pleated 1" - Replaced today Filter Size and Picture of filter: - 18x18x1 Condition of Indoor Coil: - Good - Clean Location, Type, and Picture of Outdoor Unit: - Side of House - Heat Pump Condition of Outdoor Coil: - Good - Clean - Cleaned today Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Contactor - Electrical Wiring Inspected these components on your system and they are in good condition and working properly at this time: - Blower Wheel - Secondary Drain Pan - Pri
Today, I arrived on site to perform a summer time maintenance on your HVAC equipment. Here is a summary of my findings and recommendations: Overall Equipment Condition: - Fair Location, Type, and Picture of Indoor Unit: - Closet - Air Handler Area Unit Services: - Whole House Filtration: - Pleated 2-6" filter replaced today Filter Size and Picture of filter: - 20x25 Condition of Indoor Coil: - Poor, cleaned Location, Type, and Picture of Outdoor Unit: - Back Yard - Heat Pump Condition of Outdoor Coil: - Fair, cleaned today Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Compressor Run Capacitor - Contactor - Electrical Wiring - Compressor - Condenser Fan Motor Inspected these components on your system and they are in good condition and working properly at this time: - Blower Wheel - Primary Drain Pan - Electrical Wires Secured Tested for Carbon Monoxide: -
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Attic - Type: Furnace - Picture: [Attach picture] Area Unit Services: - Whole house Filtration: - Washable - Washed today Filter: - Size: 20x25 - Picture: [Attach picture] Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: [Attach picture] Condition of Outdoor Coil: - Good - Cleaned today Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Secondary Drain Pan - Primary Drain Pan - Electrical Wires Secured Tested and cleared condensate drain system: - Cleared Drain Line - Cleaned Out Primary Pan - Tested Safety Switch - Cleaned Out Secondary
Performed a mini split cleaning on your Daikin mini split system for greater efficiency and indoor air quality. Restored power to unit and did a final check on the unit. Everything is working properly at this time.
Today we preformed the summer time maintenance on all 3 of your Heat pumps. I tested each systems operation. I cleaned and cleared the drain lines and cleaned the condensate pump. I also verified the temperature split on each unit. I also cleaned the outdoor units all systems are operating properly at this time. Thank you for your business today. Monticello, Florida.
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Attic, Garage - Type: Air Handler - Picture: Available Area Unit Services: - Right side of house Filtration: - Pleated 1" - Replaced today Filter Size and Picture: - 12x18x1 - 12x12x1 - 18x18x1 - Pictures available Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Back Yard - Type: Heat Pump - Picture: Available Condition of Outdoor Coil: - Good - Clean - Cleaned today Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Contactor - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Secondary Drain Pan - Primary Drain Pan - Electrical Wires Secured Tested for Carbon Monoxide: - N/A Return Air Temperature: - 76.5 Deg
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Attic - Type: Air Handler - Picture: [Attach picture] Area Unit Services: - Whole house Filtration: - Pleated 2-6" filter replaced today Filter: - Size: 20x25x4 - Picture: [Attach picture] Condition of Indoor Coil: - Good and clean Outdoor Unit: - Location: Front Yard - Type: Heat Pump - Picture: [Attach picture] Condition of Outdoor Coil: - Good and clean Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Compressor Start Capacitor - Contactor - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Secondary Drain Pan - Primary Drain Pan - Electrical Wires Secured Tested condensate drain system: - Cleared drain line - Cleaned out primary pan - Cleaned out secondary pan - Tested saf
Upon arrival, I found the customers Goodman package unit not cooling properly due to a bad condenser fan motor, and a bad capacitor for the indoor blower motor. I sent the customer an estimate to replace the condenser motor and indoor motor capacitor. She approved both of the estimates. After installing the condenser fan motor and the capacitor the system come on and started cooling. I then found the system to be low on Freon (410A). I sent the customer an estimate for 3 pounds of freon. The system holds almost 11 pounds of 410A. The estimate was approved. The 3 pounds of Freon got the pressures up where they need to be. The customer was not interested in a new system at the moment.Your system is operating properly at this time.
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: Good Indoor Unit: Location: Package Unit Picture: Available Area Unit Services: Whole home Filtration: Replaced today Filter Size: Sg600 Picture of filter: Available Indoor Coil: Condition: Good, Clean Outdoor Unit: Location: Back Yard Type: Package Unit Picture: Available Outdoor Coil: Condition: Good, Clean Electrical Components (Working Properly): Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Electrical Components (Not Working Properly): None Inspected Components (Good Condition and Working Properly): Blower Wheel Primary Drain Pan Electrical Wires Secured Inspected Components (Poor Condition and Not Working Properly): None Other Work Completed: Cleared Drain Line Cleaned Out Primary Pan Wore Shoe Covers Dusted the Ther
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: Fair Location, Type, and Picture of Indoor Unit: Closet Air Handler Area Unit Services: Whole home Filtration: Pleated 1" Replaced today Filter Size and Picture of filter: 20x20x1 Condition of Indoor Coil: Fair Clean Location, Type, and Picture of Outdoor Unit: Back Yard Heat Pump Condition of Outdoor Coil: Good Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Inspected these components on your system and they are in good condition and working properly at this time: Blower Wheel Primary Drain Pan Electrical Wires Secured Tested these electrical components on your equipmen
Today I performed a summertime tune up on your Grand Aire heat pump unit. Everything is working properly at this time. Thank you for your business. Monticello FL
Today I performed a summertime tune up on your Trane heat pump unit. Everything is working properly at this time. Thank you for your business. Monticello FL
Today I performed a summertime tune up on your Carrier heat pump unit. Everything is working properly at this time. Thank you for your business. Monticello FL
Today I performed a summertime maintenance on your system in Tallahassee,Fl. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-6031-C1DF8C11EE1242BC9EE41C265E47D4CD
Today I performed a summertime maintenance on your system in Tallahassee,Fl.
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: Good Indoor Unit: Type: Mini Split Location: Office and storeroom Picture: [Attach picture] Filtration: Washable filter Filter size: Mini split washable filter Filter condition: Washed today Indoor Coil: Good condition Outdoor Unit: Type: Mini Split Condenser Location: Side of house Picture: [Attach picture] Outdoor Coil: Good condition Tested and inspected electrical components: Blower Motor: Working properly within manufacturers recommended specs and amperage's Electrical Wiring: Working properly within manufacturers recommended specs and amperage's Inspected components in good condition and working properly: Blower Wheel Primary Drain Pan Electrical Wires Secured Tested for Carbon Monoxide: N/A Temperature readings: Return Air Temperature: 72.0 degrees Fahrenheit Supply Air Temperature: 50.0 degrees Fahrenheit Condensate Dr
Today, I arrived on site to perform a summer time maintenance on your HVAC equipment. Here is a summary of the work completed: Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Package Unit, Furnace Area Unit Services: The package unit is located outside and services the entire house Filtration: Pleated 1", Checked Today Filter Size and Picture of filter: 20x25x1 Condition of Indoor Coil: Good, Clean Location, Type, and Picture of Outdoor Unit: Side of House, Straight Cool, Package Unit Condition of Outdoor Coil: Good, Clean, Cleaned Today I also tested and inspected various electrical components on your equipment, all of which are working properly within manufacturers recommended specs and amperage's. Additionally, I inspected components such as the blower wheel, burners, and primary drain pan, all of which are in good condition. After testing for Carbon Monoxide (0.00 PPM), I checked the return air temperature (70.3 degrees Fahrenheit) and supply air temp
Today, I performed a thorough maintenance check on your HVAC system. Here is a summary of the work completed: Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Attic, Closet, Furnace Area Unit Services: Furnace is in the upstairs closet attic and services the downstairs area Filtration: Accordian, Replaced Today Filter Size and Picture of filter: 201 filter Condition of Indoor Coil: Good, Clean Location, Type, and Picture of Outdoor Unit: Back Yard, Straight Cool Condition of Outdoor Coil: Good, Clean, Cleaned Today During the maintenance check, I tested and inspected various electrical components on your equipment. Here are the results: Blower Motor Inducer Draft Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring I also inspected the following components on your system: Blower Wheel Primary Drain Pan Electrical Wires Secured Additionally, I conducted tests for Carbon Monoxide (0.00 PPM), checked Re
Today, I performed a summer time maintenance on your HVAC equipment. Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Closet, Air Handler Area Unit Services: The air handler is in the hallway closet and services the entire house Filtration: Pleated 1", Replaced Today Filter Size and Picture of filter: 20x20x1 Condition of Indoor Coil: Good, Clean Location, Type, and Picture of Outdoor Unit: Side of House, Heat Pump Condition of Outdoor Coil: Good, Clean, Cleaned Today I also tested and inspected various electrical components on your equipment, all of which are working properly within manufacturers recommended specs and amperage's. These components include: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring Additionally, I inspected components such as the Blower Wheel, Primary Drain Pan, and ensured that electrical wires are secured. All these components are in good condition and working prope
Today, I performed a summer time maintenance on your HVAC equipment. Here is a summary of the work completed: Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Garage, Furnace Area Unit Services: The furnace is in the garage and services the entire house Filtration: Pleated 2-6", Replaced Today Filter Size and Picture of filter: 20x20x4 Condition of Indoor Coil: Fair Location, Type, and Picture of Outdoor Unit: Back Yard, Straight Cool Condition of Outdoor Coil: Good, Cleaned Today Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: Blower Motor, Inducer Draft Motor, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperage's: N/A Inspected these components on your sy
Today, I performed a summer time maintenance on your HVAC equipment. The overall equipment condition is good. The indoor unit is located in the attic and is an air handler servicing the main living area. The filtration system consists of a pleated 1" filter, which was replaced and checked today. The filter size is 20x25x1. The indoor coil is in good condition, cleaned with a brush today, and is clean. The outdoor unit is located on the side of the house in the front yard and is a heat pump. The outdoor coil is in good condition, clean, and was cleaned today. I also tested and inspected various electrical components on your equipment, all of which are working properly within manufacturers recommended specs and amperages. These components include the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, defrost control board, and electrical wiring. I inspected the blower wheel, primary drain pan, and ensured that the
HVAC Repairs: In response to a client reporting weak airflow from their HVAC system, I conducted a detailed airflow analysis. By addressing duct restrictions and optimizing airflow, I enhanced the system's performance, delivering improved comfort and efficiency.
Today, I performed a winter time maintenance check on your HVAC equipment. - I arrived on site and found that the overall equipment condition is good. - The indoor unit is located in the attic and is an air handler servicing the whole house. - The filtration system uses pleated 2-6" filters, with a filter size of 20x30. - The indoor coil is in good, clean condition. - The outdoor unit, a heat pump, is located on the side of the house and has a good, clean outdoor coil. I tested and inspected the following electrical components on your equipment and found them to be working properly within the manufacturers' recommended specs and amperages: - Blower Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring - Electric Heat Strip Kit Safety's I also inspected other components of your system, including: - Blower Wheel - Secondary Drain Pan - Primary Drain Pan - Ele
Today, I performed a comprehensive maintenance check on your HVAC system located in the garage, which services your whole house. Here is a summary of my findings: - Overall Equipment Condition: Good - Location, Type, and Picture of Indoor Unit: Garage, Air Handler - Area Unit Services: Whole house - Filtration: Pleated 2-6", Replaced Today - Filter Size and Picture of filter: 20x20 - Condition of Indoor Coil: Good, Clean - Location, Type, and Picture of Outdoor Unit: Side of House, Heat Pump - Condition of Outdoor Coil: Good, Clean During the maintenance check, I tested and inspected various electrical components on your equipment, all of which are working properly within the manufacturers' recommended specifications and amperage's. These components include the blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, electrical wiring, and electric heat strip kit safety's. I also inspected other components on your system
I arrived on site and performed a winter time maintenance on your HVAC equipment. Here is a summary of the work completed: - Overall Equipment Condition: Good - Location, Type, and Picture of Indoor Unit: Closet, Air Handler - Area Unit Services: Right side of house - Filtration: Pleated 2-6", Replaced Today - Filter Size and Picture of filter: 20x25 - Condition of Indoor Coil: Good, Clean - Location, Type, and Picture of Outdoor Unit: Side of House, Heat Pump - Condition of Outdoor Coil: Good, Clean - Tested and inspected the following electrical components on your equipment, all working properly within manufacturers recommended specs and amperage's: Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Defrost Control Board, Electrical Wiring - Inspected the following components on your system, all in good condition and working properly: Blower Wheel, Primary Drain Pan, Electrical Wires Secured - Tested for Carbon Mono