Exceptional AC & Heating Service In Tallahassee, FL
Are you looking for a true partner when it comes to your home or company’s comfort needs? Connect with the professionals at Benson’s Heating & Air Conditioning! We are Tallahassee’s top choice for AC and heating services, with our high quality services, affordable prices and incredible offers. Our technicians are highly trained and NATE certified, and our company regularly wins top awards in customer service.
Call us now at 850-562-3132 for fast, reliable HVAC services for your home!
Our Cooling and Heating Services in Tallahassee
The comprehensive comfort services we offer include repair, replacement and maintenance on:
With incredible service that is guaranteed to get your AC and heating system working well for years to come, Benson’s is the easy choice in Tallahassee! Our team is not only experienced in air conditioning and heating, we are also proud NADCA air duct cleaning certified! Connect with us for professional air duct cleaning services as well as indoor air quality products and services.
Full HVAC Contractor Services In Tallahassee
Benson's Heating and Air Conditioning proudly provides full home comfort services throughout Tallahassee. Our service area includes all surrounding suburbs of the city as well, including Bradfordville, Lake Lamonia and Meridian. We're available 24/7 for any AC repair emergency too. Just give us a call anytime, day or night, and we'll be there ASAP to get your home cool and comfortable again.
We invite you to read some of our reviews below from customers in your neighborhood. They show our commitment to our customers with every job we do. Or, to speak with one of our team members, contact us today at 850-562-3132 and we’ll be happy to help.
Tallahassee FL HVAC Company FAQs
A central AC unit typically has a lifespan of 15 to 20 years, but this can vary based on things like the unit's make and model, the quality of its installation, and how well it's maintained. High-quality units with proper care and regular maintenance can often reach the upper end of that range or even surpass it. However, as the unit ages, it may become less energy-efficient and require more frequent repairs. Ultimately, regular maintenance and timely replacement when necessary can help maximize the lifespan and performance of a central AC unit.
The best time to replace an AC in Tallahassee, FL, is typically during the cooler months, specifically in the late fall or winter. This is because demand for air conditioning services is lower during these seasons, which can lead to better availability from HVAC contractors and potentially lower installation costs. Additionally, replacing the AC before the hot and humid summer months ensures your home stays comfortable when you need it most. Planning ahead and scheduling the replacement during the off-peak season is generally recommended for convenience and cost-effectiveness.
In Tallahassee, FL, where air conditioning is frequently used due to the hot and humid climate, it's advisable to service your AC unit at least once a year. Ideally, scheduling maintenance before the peak cooling season in the spring ensures that your system is in top condition for the scorching summer months. However, some homeowners choose to service their AC units twice a year, including a checkup in the fall before the heating season begins. Regular maintenance can optimize energy efficiency, extend the unit's lifespan, and prevent costly breakdowns.
Regular HVAC maintenance in Tallahassee, FL, offers several benefits. It ensures your system runs efficiently, reducing energy costs and preventing unexpected breakdowns during peak usage. Maintenance helps identify and address minor issues before they become major problems, extending the lifespan of your equipment. It also improves indoor air quality by keeping filters and ducts clean, which is crucial in Tallahassee’s humid climate. Overall, regular maintenance provides consistent comfort and reliability, ensuring optimal performance year-round.
Recent Jobs and Reviews in Tallahassee, FL
Our Local Reviews by City
- Alligator Point, FL (32)
- Altamonte Springs, FL (1)
- Attapulgus, GA (4)
- Bainbridge, GA (12)
- Boston, GA (6)
- Bristol, FL (8)
- Cairo, FL (1)
- Cairo, GA (11)
- Carrabelle, FL (26)
- Chattahoochee, FL (13)
- Climax, GA (5)
- Crawfordville, FL (192)
- Eastpoint, FL (7)
- Greenville, FL (18)
- Havana, FL (356)
- Lamont, FL (14)
- Madison, FL (14)
- Meigs, GA (2)
- Metcalf, GA (1)
- Midway, FL (31)
- Monticello, FL (275)
- Mount Pleasant, TN (1)
- Ochlockonee Bay, FL (3)
- Panacea, FL (63)
- Panama City Beach, FL (1)
- Quincy, FL (221)
- Quincy Historic District, FL (5)
- Saint George Island, FL (6)
- Saint Teresa, FL (14)
- Seffner, FL (1)
- Sopchoppy, FL (12)
- Tallahassee, FL (11977)
- Thomasville, GA (23)
- Virgie, KY (1)
- Whigham, GA (2)
Job Locations and Reviews
Today, I arrived on site to perform winter maintenance on the HVAC equipment. - **Overall Equipment Condition:** Good - **Indoor Unit Location:** Closet, Air Handler - **Area Served:** Bedrooms - **Filtration:** Pleated 2-6", replaced today - **Filter Size:** 20x25 hw - **Indoor Coil Condition:** Good, clean; brush cleaned today - **Outdoor Unit Location:** Side of House, Heat Pump - **Outdoor Coil Condition:** Good, clean - **Electrical Components Tested:** - **Working Properly:** Blower Motor, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Defrost Control Board, Electrical Wiring - **Not Working Properly:** N/A - **Component Inspection:** - **In Good Condition:** Blower Wheel, Electrical Wires Secured, Primary Drain Pan, Secondary Drain Pan - **In Poor Condition:** N/A - **Carbon Monoxide Test:** N/A - **Temperature Readings:** - **Return Air Temperature:** 76.0°F - **Supply Air Temperature:** 106.0°F - **Condensate Drai
Today, I arrived on site to perform a winter maintenance check on the HVAC equipment. **Overall Equipment Condition** - Equipment condition rated as good. **Indoor Unit Details** - Location: Garage, Attic - Type: Air Handler - Filtration: Pleated 2-6", replaced today - Filter Size: 20x20 Flanders - Indoor Coil Condition: Good, but dirty **Outdoor Unit Details** - Location: Side of House - Type: Heat Pump - Outdoor Coil Condition: Good and clean **System Components Inspection** - Inspected components in good condition: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - Secondary Drain Pan - No components found in poor condition. **Temperature Readings** - Return Air Temperature: 74.0°F - Supply Air Temperature: 113.0°F **Condensate Drain System** - Cleared drain line and cleaned out primary pan. **Technician Recommendations** - Duct cleaning - Install UV light - Install air purifier Overall, the system is functioning well, with a few recommendations for imp
Today I performed a wintertime tuneup on your Lennox heat pump unit. Everything is working properly at this time. Thank you for your business. Tallahassee FL
Today, I arrived on site to perform winter maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment condition is good. **Indoor Unit Details** - Location: Garage - Type: Air Handler - Filtration: Pleated 1" - Filter Size: 20x25x1 - Indoor Coil Condition: Good, clean **Outdoor Unit Details** - Location: Side of House - Type: Heat Pump - Outdoor Coil Condition: Good, clean **Electrical Components Tested** - All components tested and functioning within manufacturer specifications: - Blower Motor - Condenser Fan Motor - Compressor - Heat Strip Kit - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring **Inspections Conducted** - Components in good condition: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - Secondary Drain Pan - No components found in poor condition. **Temperature Readings** - Return Air Temperature: 67.0°F - Supply Air Temperature: 102.0°F **Condensate Dra
**Job Summary** Today, I arrived on site to perform a winter maintenance check on the HVAC equipment. **Overall Equipment Condition** - Equipment condition is good. **Indoor Unit Details** - Location: Closet - Type: Air Handler - Services: Whole house - Filtration: Pleated 1", checked today - Indoor Coil: Good and clean **Outdoor Unit Details** - Location: Side of House - Type: Heat Pump - Outdoor Coil: Good and clean, cleaned today **Electrical Components Tested** - All tested components are functioning properly within manufacturer specifications: - Blower Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring **Inspections** - Components in good condition: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - No components found in poor condition. **Temperature Readings** - Return Air Temperature: 75.0°F - Supply Air Temperature: 110.0°F
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition Equipment condition is good. Indoor Unit Details Location: Attic, Air Handler in the laundry room. Services the entire house. Filtration: Pleated 1", customer declined filters and will provide their own. Filter sizes: (1) 20x25x1 and (1) 16x20x1. Indoor coil condition: Good and clean. Outdoor Unit Details Location: Back yard, Heat Pump. Outdoor coil condition: Good and clean. Electrical Components Tested All tested components are working properly within manufacturer specifications: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Electrical Wiring System Inspections Inspected components in good condition: Blower Wheel Primary Drain Pan Secondary Drain Pan Electrical wires secured No components in poor condition. Temperature Readings Return air temperature: 83.4°F Supply air temperature: 120.2°F Condensate Drain System Clea
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment condition rated as fair. **Indoor Unit Details** - Location: Attic - Type: Whole house system - Filtration: Pleated 1" filter replaced today - Filter Size: 20x20x1 - Indoor Coil Condition: Fair **Outdoor Unit Details** - Location: Back Yard - Outdoor Coil Condition: Fair **Electrical Components Tested** - All components tested and functioning within manufacturer specifications: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring - Heat Strip Kit - Electric Heat Strip Kit Safety's **Inspections** - Components in good condition: - Blower Wheel - Primary Drain Pan - Electrical Wires secured - No components found in poor condition. **Temperature Readings** - Return Air Temperature: 74.0°F - Supply Air Temperature: 52.0°F **Condensate Drain System*
Today, I arrived on site to perform winter maintenance on the HVAC equipment. - **Overall Equipment Condition:** Good - **Indoor Unit Location:** Garage, Closet (Air Handler) - **Area Unit Services:** Whole home - **Filtration:** - Type: Pleated 1" - Checked and replaced today - Filter Size: 20x25x1 - **Indoor Coil Condition:** Good, Clean - **Outdoor Unit Location:** Back Yard (Heat Pump) - **Outdoor Coil Condition:** Good, Clean **Electrical Components Tested:** - All components functioning properly within manufacturer specifications: - Blower Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring **Inspections:** - **Good Condition:** - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - **Poor Condition:** None reported **Additional Checks:** - Carbon Monoxide test: N/A - Return Air Temperature: 70.0°F - Su
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment condition is good. **Indoor Unit Details** - Location: Attic - Type: Air Handler - Services: Whole house - Filtration: Customer declined filters; will provide their own. - Filter Size: 24x24x1 - Indoor Coil: Good condition, cleaned with a brush today. **Outdoor Unit Details** - Location: Back Yard - Type: Heat Pump - Outdoor Coil: Good condition, cleaned today. **Electrical Components Tested** - All components tested and working properly: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring - Heat Strip Kit **Inspections** - Components in good condition: - Blower Wheel - Primary Drain Pan - Secondary Drain Pan - Electrical Wires Secured - No components in poor condition. **Safety Checks** - Carbon Monoxide levels tested
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. - **Overall Equipment Condition**: Good - **Indoor Unit**: Located in the closet; type is air handler. - **Service Area**: Whole house - **Filtration**: Replaced washable, pleated filter (2-6") with a 20x20 hw due to loud whistling in the filter cabinet. - **Indoor Coil Condition**: Good and clean - **Outdoor Unit**: Located on the side of the house; type is heat pump. - **Outdoor Coil Condition**: Good and clean - **Electrical Components Tested**: - Blower Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring - **Electrical Components Not Working**: N/A - **Inspected Components in Good Condition**: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - Secondary Drain Pan - **Inspected Components in Poor Condition**: N/A - **Carbon Monoxide Test**:
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. - **Overall Equipment Condition**: Fair - **Indoor Unit**: Located in the attic; air handler servicing the 2nd floor - **Filtration**: Replaced pleated 1" filter (size: 20x20x1) - **Indoor Coil Condition**: Good; brush cleaned today - **Outdoor Unit**: Positioned on the side of the house; heat pump - **Outdoor Coil Condition**: Fair; cleaned today - **Electrical Components Tested**: - All components including blower motor, condenser fan motor, compressor, contactor, defrost control board, electric heat strip kit safety's, and electrical wiring are functioning properly within manufacturer specifications. - Noted issues with compressor run capacitor and condenser fan motor run capacitor. - **Inspected Components**: - Good condition: blower wheel, secondary drain pan, primary drain pan, electrical wires secured - Poor condition: N/A - **Temperature Readings**: - Return air te
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment condition is good. **Indoor Unit Details** - Location: Crawl Space - Type: Furnace - Services: Whole house - Filtration: Pleated 2-6" - Filter Size: 16x25x4 - Condition of Indoor Coil: Good, clean **Outdoor Unit Details** - Location: Back Yard - Type: Straight Cool - Condition of Outdoor Coil: Good, clean **Electrical Components Tested** - Blower Motor: Working properly - Inducer Draft Motor: Working properly - Condenser Fan Motor: Working properly - Compressor: Working properly - Compressor Run Capacitor: Working properly - Fan Run Capacitor: Working properly - Contactor: Working properly - Electrical Wiring: Working properly **Inspections** - Components in good condition: Blower Wheel, Burners, Exhaust Flue, Heat Exchanger, Primary Drain Pan, Electrical Wires secured - No components found in poor condition **Testing Results** - Carbon Monoxi
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition Equipment condition: Good Indoor Unit Details Location: Garage attic Type: Air Handler Services: Entire house Filtration: Pleated 2-6", replaced today Filter Size: 20x25 Honeywell Indoor Coil Condition: Good, clean Outdoor Unit Details Location: Side of house Type: Heat Pump Outdoor Coil Condition: Good, cleaned today Electrical Components Inspected Blower Motor: Working properly Heat Strip Kit: Working properly Condenser Fan Motor: Working properly Compressor: Working properly Compressor Run Capacitor: Working properly Fan Run Capacitor: Working properly Contactor: Working properly Electrical Wiring: Working properly Components Inspected Blower Wheel: Good condition Primary Drain Pan: Good condition Secondary Drain Pan: Good condition Electrical Wires: Secured Testing Results Return Air Temperature: 76.1°F Supply Air Temperature: 120.2°F Condensate Drain System: Cleared drai
Today, I arrived on site to perform winter maintenance on the HVAC equipment. **Equipment Condition** - Overall equipment condition: Good - Indoor unit located in the garage attic; type: furnace - Outdoor unit located on the side of the house; type: straight cool **Filtration** - Filter type: Pleated 2-6" - Filter size: 20x20x5 - Filter checked and replaced today **Coil Condition** - Indoor coil: Good and clean - Outdoor coil: Good and clean **Electrical Components** - Tested and inspected the following components, all functioning properly: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Furnace Control Board **System Inspection** - Inspected components in good condition: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - Secondary Drain Pan - No components found in poor condition **Safety Checks** - Carbon Monoxide level: 0.00 PPM
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment condition: Good **Indoor Unit Details** - Location: Garage - Type: Air Handler - Filtration: Pleated 2-6", checked today - Filter size: 20x25 - Indoor coil condition: Good, cleaned with a brush today **Outdoor Unit Details** - Location: Side of House - Type: Heat Pump - Outdoor coil condition: Good, cleaned today **Electrical Components Tested** - All components tested: - Blower Motor - Inducer Draft Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring - All components are working properly within manufacturer’s recommended specs and amperages. **System Inspections** - Components in good condition: - Primary Drain Pan - Secondary Drain Pan - Electrical Wires Secured - Blower Wheel - No components in poor condition. **Testing Resu
**Job Summary** Today, I arrived on site to perform summer maintenance on your HVAC equipment. **Overall Equipment Condition** - Equipment condition is good. **Indoor Unit Details** - Location: Garage - Type: Air Handler - Services: Whole house - Filtration: Antimicrobial, checked today - Filter Size: 20x25x1 - Indoor Coil Condition: Good, clean **Outdoor Unit Details** - Location: Side of House - Type: Heat Pump - Outdoor Coil Condition: Good, clean **Electrical Components Tested** - All components tested and working properly: - Blower Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Contactor - Electrical Wiring - Electric Heat Strip Kit Safety's **Inspections** - Components in good condition: - Blower Wheel - Primary Drain Pan - Electrical Wires secured - No components found in poor condition. **Temperature Readings** - Return Air Temperature: 75.0°F - Supply Air T
Job Summary Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition Equipment condition rated as fair. Indoor Unit Details Location: Attic Type: Air Handler Services: Whole home Filtration: Pleated 1", replaced today Filter Size: 12x24x1 and 12x12x1 Indoor Coil Condition: Fair, clean Outdoor Unit Details Location: Side of house Type: Heat Pump Outdoor Coil Condition: Good, clean Electrical Components Tested All components tested: Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Compressor Start Capacitor, Contactor, Electrical Wiring All components are working properly within manufacturer specifications. Inspections Components in good condition: Blower Wheel, Secondary Drain Pan, Primary Drain Pan, Electrical Wires secured No components found in poor condition. Temperature Readings Return Air Temperature: 73.0°F Supply Air Temperature: 105.0°F Condensate Drain System Clea
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC system. **Overall Equipment Condition** - Equipment condition rated as good. **Indoor Unit Details** - Location: Attic - Type: Furnace - Services: Whole house - Filtration: Pleated 2-6", replaced today - Filter Size: 20x25x4 - Indoor Coil Condition: Clean, fair **Outdoor Unit Details** - Location: Back yard - Type: Straight cool - Outdoor Coil Condition: Good, cleaned today **Electrical Components Tested** - Blower Motor: Working properly - Inducer Draft Motor: Working properly - Electrical Wiring: Working properly - Furnace Control Board: Working properly - No components found not working properly. **Inspected Components** - Good condition: Blower Wheel, Burners, Exhaust Flue, Heat Exchanger, Primary Drain Pan, Electrical Wires Secured, Secondary Drain Pan - No components found in poor condition. **Safety Checks** - Carbon Monoxide Test: 0.00 PPM - Return Air Temperature: 79.0°F - Supply Air Temp
Today, I arrived on site to perform winter maintenance on the HVAC system. **Overall Equipment Condition** - Equipment condition is good. **Indoor Unit Details** - Location: Attic - Type: Furnace - Services: Whole home - Filtration: Pleated 2-6" - Filter Size: 20x25x5 - Customer declined filters and will provide their own. - Indoor coil condition: Good and clean. **Outdoor Unit Details** - Location: Side of House - Type: Straight Cool - Outdoor coil condition: Good and clean. **Electrical Components Tested** - All components tested: Blower Motor, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Defrost Control Board, Electrical Wiring. - All components are working properly within manufacturer’s recommended specs and amperages. **Inspections** - Inspected components: Blower Wheel, Electrical Wires, Primary Drain Pan, Secondary Drain Pan. - All inspected components are in good condition and functioning properly. **Carbon Monoxide Test** - Re
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. - **Overall Equipment Condition:** Good - **Indoor Unit:** - Location: Crawl Space - Type: Air Handler - Filtration: Pleated 2-6", checked today - Filter Size: 20x25 - Condition of Indoor Coil: Good, cleaned with a brush today - **Outdoor Unit:** - Location: Side of House - Type: Heat Pump - Condition of Outdoor Coil: Good, cleaned today - **Electrical Components Tested:** - All components (Blower Motor, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Electrical Wiring) are working properly within manufacturer’s recommended specs and amperages. - **Inspections:** - Good condition: Blower Wheel, Primary Drain Pan, Secondary Drain Pan, Electrical Wires secured - Poor condition: N/A - **Carbon Monoxide Test:** 0.00 PPM - **Temperature Readings:** - Return Air Temperature: 72.0°F - Supply Air Temperature: 99
Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition: Good Indoor Unit: Location: Garage attic Type: Air Handler Services: Entire house Filtration: Pleated 2-6", replaced today Filter Size: 20x25 Honeywell filter Indoor Coil Condition: Good Outdoor Unit: Location: Side of house Type: Heat Pump Outdoor Coil Condition: Good, cleaned today Electrical Components Tested: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring All components are working properly within manufacturer’s recommended specs and amperages. Inspected Components: Blower Wheel: Good condition Primary Drain Pan: Good condition Secondary Drain Pan: Good condition Electrical Wires: Secured Carbon Monoxide Test: N/A Temperature Readings: Return Air: 69.4°F Supply Air: 121.4°F Condensate Drain System: Cleared drain line Cleaned out primary and secondary pans Tested safety switch Additional Actions
Performed a winter time tune up on your hvac system. Everything is working properly at this time. I recommend replacing the uv light on your air purifier, I will send an estimate to replace. Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition Equipment condition rated as fair. Indoor Unit Details Location: Closet Type: Air Handler Services: Whole house Filtration: Pleated 2-6" Filter Size: 20x20x4 Indoor Coil: Good condition, cleaned with a brush today. Outdoor Unit Details Location: Side of House Type: Heat Pump Outdoor Coil: Good condition, clean. Electrical Components Tested and inspected: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Defrost Control Board Electrical Wiring All components working properly within manufacturer’s recommended specs. Inspections Components in good condition: Blower Wheel Primary Drain Pan Electrical
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. - **Overall Equipment Condition**: Good - **Indoor Unit**: - Location: Attic - Type: Air Handler - Services: Whole house - Filtration: Pleated 1" filter replaced today - Filter Size: 20x20x1 - Indoor Coil Condition: Good, clean - **Outdoor Unit**: - Location: Side of House - Type: Heat Pump - Outdoor Coil Condition: Good, clean - **Electrical Components Tested**: - All components including Blower Motor, Condenser Fan Motor, Heat Strip Kit, Compressor, Capacitors, Contactor, and Electrical Wiring are functioning properly within manufacturer specifications. - **Inspected Components**: - All components including Blower Wheel, Drain Pans, and Electrical Wires are in good condition. - **Carbon Monoxide Test**: Not applicable - **Temperature Readings**: - Return Air: 72.0°F - Supply Air: 93.5°F - **Condensate Drain System**: - Cleared drain line, cleaned primary a
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. - **Overall Equipment Condition:** Good - **Indoor Unit Location and Type:** Attic, Crawl Space, Furnace, Air Handler - **Area Unit Services:** Whole house - **Filtration:** Pleated 1" filter replaced today - **Filter Size:** 20x20x1 - **Indoor Coil Condition:** Good, clean; brush cleaned today - **Outdoor Unit Location and Type:** Side of House, Heat Pump, Straight Cool - **Outdoor Coil Condition:** Good, clean; cleaned today **Electrical Components Testing** - **Components Tested and Working Properly:** - Blower Motor - Inducer Draft Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring - **Components in Poor Condition:** N/A **System Inspection** - **Components in Good Condition:** - Blower Wheel - Burners - Exhaust Flue - Heat Exchanger - Primary Dr
Job Summary Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition Equipment condition rated as fair. Indoor Unit Details Location: Attic Type: Air Handler Filtration: Pleated 1", replaced today Filter Size: 20x20x1 Indoor Coil Condition: Fair, clean Outdoor Unit Details Location: Side of House Type: Heat Pump Outdoor Coil Condition: Good, clean Electrical Components Tested All components tested: Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Compressor Start Capacitor, Contactor, Electrical Wiring All components are working properly within manufacturer’s recommended specs and amperages. Inspections Conducted Components in good condition: Blower Wheel, Secondary Drain Pan, Primary Drain Pan, Electrical Wires Secured No components found in poor condition. Temperature Readings Return Air Temperature: 74.0°F Supply Air Temperature: 110.0°F Condensate Drain System Cleared