Exceptional AC & Heating Service In Tallahassee, FL
Are you looking for a true partner when it comes to your home or company’s comfort needs? Connect with the professionals at Benson’s Heating & Air Conditioning! We are Tallahassee’s top choice for AC and heating services, with our high quality services, affordable prices and incredible offers. Our technicians are highly trained and NATE certified, and our company regularly wins top awards in customer service.
Call us now at 850-562-3132 for fast, reliable HVAC services for your home!
Our Cooling and Heating Services in Tallahassee
The comprehensive comfort services we offer include repair, replacement and maintenance on:
With incredible service that is guaranteed to get your AC and heating system working well for years to come, Benson’s is the easy choice in Tallahassee! Our team is not only experienced in air conditioning and heating, we are also proud NADCA air duct cleaning certified! Connect with us for professional air duct cleaning services as well as indoor air quality products and services.
Full HVAC Contractor Services In Tallahassee
Benson's Heating and Air Conditioning proudly provides full home comfort services throughout Tallahassee. Our service area includes all surrounding suburbs of the city as well, including Bradfordville, Lake Lamonia and Meridian. We're available 24/7 for any AC repair emergency too. Just give us a call anytime, day or night, and we'll be there ASAP to get your home cool and comfortable again.
We invite you to read some of our reviews below from customers in your neighborhood. They show our commitment to our customers with every job we do. Or, to speak with one of our team members, contact us today at 850-562-3132 and we’ll be happy to help.
Tallahassee FL HVAC Company FAQs
A central AC unit typically has a lifespan of 15 to 20 years, but this can vary based on things like the unit's make and model, the quality of its installation, and how well it's maintained. High-quality units with proper care and regular maintenance can often reach the upper end of that range or even surpass it. However, as the unit ages, it may become less energy-efficient and require more frequent repairs. Ultimately, regular maintenance and timely replacement when necessary can help maximize the lifespan and performance of a central AC unit.
The best time to replace an AC in Tallahassee, FL, is typically during the cooler months, specifically in the late fall or winter. This is because demand for air conditioning services is lower during these seasons, which can lead to better availability from HVAC contractors and potentially lower installation costs. Additionally, replacing the AC before the hot and humid summer months ensures your home stays comfortable when you need it most. Planning ahead and scheduling the replacement during the off-peak season is generally recommended for convenience and cost-effectiveness.
In Tallahassee, FL, where air conditioning is frequently used due to the hot and humid climate, it's advisable to service your AC unit at least once a year. Ideally, scheduling maintenance before the peak cooling season in the spring ensures that your system is in top condition for the scorching summer months. However, some homeowners choose to service their AC units twice a year, including a checkup in the fall before the heating season begins. Regular maintenance can optimize energy efficiency, extend the unit's lifespan, and prevent costly breakdowns.
Regular HVAC maintenance in Tallahassee, FL, offers several benefits. It ensures your system runs efficiently, reducing energy costs and preventing unexpected breakdowns during peak usage. Maintenance helps identify and address minor issues before they become major problems, extending the lifespan of your equipment. It also improves indoor air quality by keeping filters and ducts clean, which is crucial in Tallahassee’s humid climate. Overall, regular maintenance provides consistent comfort and reliability, ensuring optimal performance year-round.
Recent Jobs and Reviews in Tallahassee, FL
Customers say: The reviews exhibit a positive sentiment, with a majority of them expressing satisfaction with the services provided. The positive reviews highlight the excellent service, helpfulness, professionalism, and knowledge of the technicians. The customers appreciate the prompt and efficient service, as well as the technicians' ability to address their concerns and provide solutions. Additionally, the positive reviews mention the friendly and courteous nature of the technicians, which adds to the overall positive experience. However, there are a few negative reviews, which mainly focus on minor issues or scheduling conflicts. The negative reviews mention delays, rescheduling, and technicians not showing up on time. However, these negative reviews are outweighed by the positive reviews, and the overall sentiment remains positive. In general, the reviews convey a sense of satisfaction with the services provided by the company. The positive reviews highlight the professionalism, expertise, and courteousness of the technicians, while the negative reviews mainly focus on minor issues or scheduling conflicts. Overall, the sentiment is positive, with a majority of customers expressing satisfaction with the services provided.
Our Local Reviews by City
- Alligator Point, FL (33)
- Altamonte Springs, FL (1)
- Attapulgus, GA (4)
- Bainbridge, GA (12)
- Boston, GA (6)
- Bristol, FL (8)
- Cairo, FL (1)
- Cairo, GA (11)
- Carrabelle, FL (26)
- Chattahoochee, FL (13)
- Climax, GA (5)
- Crawfordville, FL (195)
- Eastpoint, FL (7)
- Greenville, FL (18)
- Havana, FL (364)
- Lamont, FL (14)
- Madison, FL (14)
- Meigs, GA (2)
- Metcalf, GA (1)
- Midway, FL (33)
- Monticello, FL (279)
- Mount Pleasant, TN (1)
- Ochlockonee Bay, FL (3)
- Panacea, FL (64)
- Panama City Beach, FL (1)
- Quincy, FL (222)
- Quincy Historic District, FL (5)
- Saint George Island, FL (6)
- Saint Teresa, FL (14)
- Seffner, FL (1)
- Sopchoppy, FL (12)
- Tallahassee, FL (12261)
- Thomasville, GA (24)
- Virgie, KY (1)
- Whigham, GA (2)
Job Locations and Reviews
Today, I arrived on site to perform a winter maintenance check on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in a closet as an air handler. * Services the whole home. * Antimicrobial filtration system; replaced spare filters today. * Filter sizes: 12x24 and 12x18x1. * Indoor coil condition: clean and good. Outdoor Unit Details: * Located in the back yard as a heat pump. * Outdoor coil condition: clean and good. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Defrost Control Board * Electrical Wiring * Electric Heat Strip Kit Safety's Inspections: * Inspected components in good condition: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires S
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Location: Closet * Type: Air Handler * Filtration: Pleated 1" filters replaced with customer’s spare filters. * Filter Size: 20x20 * Indoor Coil: Good and clean; brush cleaned today. Outdoor Unit Details: * Location: Back Yard * Type: Heat Pump * Outdoor Coil: Good and clean; cleaned today. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring System Inspection: * Components in good condition: * Blower Wheel * Secondary Drain Pan * Electrical Wires Secured * Primary Drain Pan * No components found in poor condition. Carbon Monoxide Test: * Result: 0.00
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Rated as fair. Indoor Unit Details: * Located in the garage. * Services the whole home. * Antimicrobial filter replaced today, size 20x20. * Indoor coil condition is fair but dirty; duct cleaning is recommended. Outdoor Unit Details: * Located on the side of the house. * Outdoor coil condition is fair. Electrical Components: * Blower motor, heat strip kit, compressor, compressor run capacitor, fan run capacitor, contactor, electrical wiring, and electric heat strip kit safety were tested and are functioning properly within manufacturer specifications. Inspected Components: * Blower wheel, primary drain pan, and electrical wires are in good condition and working properly. * No components were found in poor condition. Testing Results: * Carbon monoxide test: N/A. * Return air temperature: 70.0°F. * Supply air temperature: 79.0°F. Condensate Drain System: * Cleared drain line, cleaned
Today, I arrived on site to perform a winter maintenance check on the HVAC equipment. Overall Equipment Condition: Condition rated as fair. Indoor Unit: Located in the attic, identified as an air handler. Services the whole home. Filtration system includes a pleated 1" filter, replaced today with customer-provided spare filters. Filter size is 18x18x1. Indoor coil condition is fair and clean. Outdoor Unit: Positioned on the side of the house, identified as a heat pump. Outdoor coil condition is good and clean. Electrical Components: Successfully tested and inspected the following components, all working properly within manufacturer specifications: Blower Motor Heat Strip Kit Compressor Condenser Fan Motor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring No components were found to be malfunctioning. System Inspection: Inspected components in good condition: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires secured
Found the unit heating but the inducer motor sounded terrible. I watched the maintenance technician’s video of the motor from earlier and concluded that the motor needs to be replaced. Created estimate and it was approved. We will perform the repair when parts come in. 1/14 - Replaced inducer motor per as agreed. Tested system operations and the furnace is heating properly at this time. Thank you for your business.
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Fair condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the crawl space. * Services the whole home. * Filtration system checked; pleated filter size is 20x25x4. * Indoor coil condition is fair. Outdoor Unit Details: * Positioned on the side of the house. * Outdoor coil condition is fair. Electrical Components: * All tested components are functioning properly: * Blower Motor * Inducer Draft Motor * Condenser Fan Motor * Contactor * Electrical Wiring * Furnace Control Board * No components were found to be malfunctioning. Inspections: * Good condition and functioning properly: * Blower Wheel * Primary Drain Pan * Electrical Wires Secured * Poor condition noted: * Blower Wheel * Burners * Exhaust Flue Temperature Readings: * Return Air Temperature: 75.0°F * Supply Air Temperature: 123.0°F Condensate Drain System: * Cl
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: fair. Indoor Unit: Located in the closet as a furnace. Services the whole home. Pleated filter (2-6") replaced today. Filter size: 20x25. Indoor coil condition: fair and clean. Outdoor Unit: Located on the side of the house as a straight cool unit. Outdoor coil condition: good and clean. Electrical Components: All tested components are functioning properly within manufacturer specifications: Blower Motor Inducer Draft Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring No components found to be malfunctioning. Inspected Components: Good condition and functioning: Blower Wheel Burners Exhaust Flue Heat Exchanger Primary Drain Pan Electrical Wires secured No components found in poor condition. Testing Results: Carbon Monoxide level: 0.00 PPM. Return air temperature: 68.0°F. Supply air temperatur
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the crawl space. * Type: Air Handler. * Services the whole home. * Filtration system: Pleated 1" filters. * Customer has spare filters and prefers to replace them independently. * Filter size: 16x20. Outdoor Unit Details: * Located on the side of the house. * Type: Heat Pump. * Outdoor coil condition: Good and clean. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring System Inspection: * Inspected components in good condition: * Blower Wheel * Electrical Wires Secured * Primary Drain Pan * Secondary Drain Pan * No components found in po
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: Good condition noted for the overall system. Indoor Unit Details: Located in the crawl space, identified as a furnace. Services the whole home. Filtration system consists of pleated 2-6" filters; replaced today. Customer requested additional filters for a charge; no spare filters available. Filter size is 16x20x4. Indoor Coil Condition: Fair condition observed. Outdoor Unit Details: Located in the back yard, identified as a straight cool unit. Good condition noted for the outdoor coil. Electrical Components: All tested electrical components are functioning properly within manufacturer specifications: Blower Motor Compressor Blower Run Capacitor Compressor Run Capacitor Fan Run Capacitor Contactor Furnace Control Board Electrical Wiring Inspections: Components in good condition include: Blower Wheel Burners Exhaust Flue Heat Exchanger Secondary Drain Pan Primary Drain Pan Electrical Wi
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the attic as an air handler. * Services the whole home. * Filtration system uses a pleated 1" filter. * Customer has spare filters and prefers to replace them independently. * Indoor coil is clean and in good condition. Outdoor Unit Details: * Positioned on the side of the house as a heat pump. * Outdoor coil is also clean and in good condition. Electrical Components: * All tested electrical components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring System Inspections: * Blower Wheel, Electrical Wires, Primary Drain Pan, and Secondary Drain Pan are in good condition. * No components were
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the crawl space as an air handler. * Services the whole home. * Pleated filter size of 20x20x4 checked today and found in good condition. * Indoor coil inspected and confirmed clean. Outdoor Unit Details: * Positioned on the side of the house as a heat pump. * Outdoor coil also inspected and confirmed clean. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Defrost Control Board * Electrical Wiring * Electric Heat Strip Kit Safety's System Condition: * Inspected components in good condition: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Elect
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in a closet as an air handler. * Services the whole home. * Filtration system is a pleated 1" filter, checked today. * Customer declined filters and will provide their own. * Filter size is 16x20x1. * Indoor coil is clean and in good condition. Outdoor Unit Details: * Located on the side of the house as a heat pump. * Outdoor coil is clean and in good condition. Electrical Components: * Blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring tested and are functioning properly within manufacturer specifications. Inspections: * Blower wheel, primary drain pan, and electrical wires secured are in good condition. * No components found in poor condition or malfunctioning. Temperature Readings: * Return air temperature
01/13/2025- compressor was in rotary lockout and the capacitor was weak. I reset the control boards and the core sense before replacing the warranty capacitor. The unit started working properly after the capacitor had been replaced. I have verified that the unit is heating properly at this time.
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Type: Air Handler located in a closet. * Services: Whole home. * Filtration: Pleated 1" filter checked today. * Filter Size: 20x20x1. * Indoor Coil: Good and clean condition. Outdoor Unit Details: * Type: Heat Pump located on the side of the house. * Outdoor Coil: Good and clean condition. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Defrost Control Board * Electrical Wiring * Electric Heat Strip Kit Safety's Inspections: * Components in good condition: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires secured * No component
Today, I arrived on site to perform a winter maintenance check on the HVAC equipment. Overall Equipment Condition: * Good condition noted for the entire system. Indoor Unit Details: * Located in the garage attic. * Type: Air Handler. * Serves the whole home. * Filtration system is washable and was checked today. * Filter size is 20x20. Indoor Coil Condition: * Good condition but noted as dirty. * Brush cleaning was performed today. Outdoor Unit Details: * Located on the side of the house. * Type: Heat Pump. * Outdoor coil is in good and clean condition. Electrical Components Tested: * All components tested are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring Inspections: * Blower Wheel, Electrical Wires, Primary Drain Pan, and Secondary Drain Pan are in good condition. * No components we
Today, I arrived on site to perform winter maintenance on the HVAC equipment. * Overall equipment condition is good. * Indoor unit located in the attic is a furnace. * Services the whole home effectively. * Filtration system is washable and was washed today. * Filter size is 16x20x5. * Indoor coil is in good, clean condition. * Outdoor unit located in the back yard is a straight cool system. * Outdoor coil is also in good, clean condition. Electrical components tested and found to be working properly: * Blower Motor * Inducer Draft Motor * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring No electrical components were found to be malfunctioning. Inspected components in good condition: * Blower Wheel * Burners * Exhaust Flue * Heat Exchanger * Primary Drain Pan * Electrical Wires Secured Carbon monoxide levels tested at 0.00 PPM. * Return air temperature measured at 68.0°F. * Supply air temperature measured at 115.0°F.
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: Fair condition noted for the overall system. Indoor Unit Details: Located in a closet as an air handler. Services the whole home. Filtration system includes pleated 1" filters, replaced today with customer-provided spare filters. Filter sizes: 20x20x1 and 12x12x1. Indoor coil condition is fair and clean. Outdoor Unit Details: Located in the back yard as a heat pump. Outdoor coil condition is good and clean. Electrical Component Testing: All tested electrical components are functioning properly within manufacturer specifications: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Component Inspection: Inspected components in good condition: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires Secured Temperature Readings: Return air temperature: 73.0°F Supply air tem
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in a closet as an air handler. * Services the whole home. * Antimicrobial filter checked today, size 20x20. * Indoor coil is clean and in good condition, brush cleaned today. Outdoor Unit Details: * Located on the side of the house as a heat pump. * Outdoor coil is clean and in good condition, cleaned today. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring System Inspections: * Blower Wheel, Primary Drain Pan, Secondary Drain Pan, and Electrical Wires are in good condition and working properly. * No components found in poo
01/13/2025- Upon inspection of the unit I discovered that the common wire had gotten loose and disconnected itself from the terminal, causing a break in the electrical circuit. Since the electrical circuit was broken the thermostat was blank causing the unit to remain off. I reconnected the common wire to the correct terminal and the thermostat started working properly. I then waited for the unit to turn on into to heat and aux heat. The unit is now working properly at this time.
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Condition rated as fair. Indoor Unit Details: * Located in the garage attic. * Type: Air Handler. * Serves the whole home. * Customer has spare filters but prefers to replace them independently. * Filter size unknown. Indoor Coil Condition: * Inspected and found to be good and clean. Outdoor Unit Details: * Located in the back yard. * Type: Heat Pump. * Outdoor coil condition is good and clean. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring Inspected Components: * Good condition: * Blower Wheel * Electrical Wires Secured * Primary Drain Pan * Secondary Drain Pan * No components found in poor condition. Temperature Readings: * Ret
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in a closet, type: Air Handler. * Services the whole home. * Filtration system checked with a pleated 1" filter. * Filter size: 20x24x1, in good condition. * Indoor coil inspected and found clean. Outdoor Unit Details: * Located on the side of the house, type: Heat Pump. * Outdoor coil also inspected and found clean. Electrical Components: * Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, and Electrical Wiring tested and functioning properly within manufacturer specifications. System Components: * Blower Wheel, Primary Drain Pan, and Electrical Wires secured and in good condition. * No components found in poor condition. Temperature Readings: * Return Air Temperature: 68.0°F. * Supply Air Temperature: 98.0°F. Condens
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: Condition rated as fair. Indoor Unit Details: Location: Attic Type: Air Handler Filtration: Respicare filters replaced today using customer’s spare filters. Filter Size: 19x20 Indoor Coil Condition: Fair and clean. Outdoor Unit Details: Location: Back Yard Type: Heat Pump Outdoor Coil Condition: Good and clean. Electrical Components: Tested and inspected components including: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring All components are functioning properly within manufacturer’s recommended specifications. System Inspections: Inspected components in good condition: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires secured No components found in poor condition. Temperature Readings: Return Air Temperature: 71.0 Degrees Fahrenheit Supply Air Temperature: 11
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: Good condition noted for the overall system. Indoor Unit Details: Located in the crawl space, identified as an air handler. Services the whole home. Filtration system is a pleated 1" filter; customer declined filters and will provide their own. Filter size is 16x16x1. Indoor Coil Condition: Condition rated as fair. Outdoor Unit Details: Located in the back yard, identified as a heat pump. Outdoor coil condition is good. Electrical Components: All tested components are functioning properly within manufacturer specifications: Blower Motor Compressor Blower Run Capacitor Compressor Run Capacitor Fan Run Capacitor Contactor Defrost Control Board Electrical Wiring Inspections: Components in good condition: Blower Wheel Heat Exchanger Primary Drain Pan Electrical Wires Secured No components were found in poor condition. Temperature Readings: Return Air Temperature: 70.0°F Supply Air Temper
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Location: Attic * Type: Air Handler * Filtration: Pleated 1", checked today * Filter Size: 20x25x1 * Indoor Coil Condition: Clean Outdoor Unit Details: * Location: Side of House * Type: Heat Pump * Outdoor Coil Condition: Good, clean Electrical Components: * All tested components are functioning properly within manufacturer specs: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Defrost Control Board * Electrical Wiring * Electric Heat Strip Kit Safety's System Inspections: * Components in good condition: * Blower Wheel * Primary Drain Pan * Secondary Drain Pan * Electrical Wires Secured * No components found in poor condition. Temperature Readings: * Return A
HVAC Repairs: Weak airflow from a homeowner's HVAC system prompted a service call. I conducted a thorough inspection and addressed duct obstructions. With improved airflow, the system now operates at peak efficiency, delivering enhanced comfort.