Full Air Conditioning & Heating Services in Quincy, FL
Did you know that we have served folks in the Quincy area for more than 40 years? That’s right, for over 4 decades, Benson’s Heating & Air Conditioning has provided exceptional heating and cooling services backed by our 100% satisfaction guarantee. Our local small business provides professional services with the help of our highly trained and NATE-certified technicians, who are able to accurately fix, replace or tune up your unit the right way the first time.
Call us 24/7 at 850-562-3132 for expert heating & air services you can trust!
Local Expert Cooling and Heating Service in Quincy, FL
Our comprehensive comfort services include repair, replacement and maintenance on:
We invite you to read some of our reviews below from customers in the Quincy area. We hope they demonstrate our commitment to quality and service. To learn more or to schedule a consultation, contact us today.
Quincy HVAC FAQs
A few reasons you may want to replace your HVAC system rather than repair it include:
- Your HVAC system is over 10 years old and breaks down often
- Your HVAC system requires repairs frequently
- Your HVAC system doesn't heat and cool your home effectively
Another sign you should replace your HVAC system is if your energy bills have increased dramatically. However, if your HVAC system is fairly new and the cost to repair it is less than half the cost to replace it, then it may be more cost-effective to have it repaired.
To improve your indoor air quality in your home, you can do the following:
- Clean your house often
- Replace your HVAC unit’s air filter
- Use your ventilation systems
- Purchase an air purifier
If you notice a large amount of dust in your home’s air, you can also get your air ducts inspected and cleaned to ensure that they are not contributing to your indoor air quality problem.
It costs around $3,000-$7,000 to replace a central air conditioning unit in Quincy, FL. However, the cost can fluctuate depending on:
- The size of your house
- The type of central air conditioning unit you want installed
- The cost to remove the current AC unit and install the new unit
Getting your central air conditioning system replaced can be costly, but will save you money on repairs and energy costs each year.
Recent Jobs and Reviews in Quincy, FL
Customers say: The overall tone of the reviews is positive, with a strong emphasis on the quality of service provided by the technicians. The reviews highlight the professionalism, efficiency, and friendliness of the technicians, as well as their ability to explain findings and provide options for maintenance and repairs. There are a few negative reviews, but they are not a dominant trend and do not represent a clear, recurring pattern. The reviews also mention the helpfulness and responsiveness of the customer service call center, which is appreciated by many customers.
Our Local Reviews by City
- Alligator Point, FL (41)
- Altamonte Springs, FL (1)
- Attapulgus, GA (4)
- Bainbridge, GA (13)
- Boston, GA (6)
- Bristol, FL (8)
- Cairo, FL (1)
- Cairo, GA (12)
- Carrabelle, FL (27)
- Chattahoochee, FL (13)
- Climax, GA (5)
- Crawfordville, FL (223)
- Eastpoint, FL (7)
- Greenville, FL (18)
- Havana, FL (393)
- Lamont, FL (14)
- Lanark Village, FL (1)
- Madison, FL (15)
- Meigs, GA (2)
- Metcalf, GA (1)
- Midway, FL (39)
- Monticello, FL (305)
- Mount Pleasant, TN (1)
- Ochlockonee Bay, FL (3)
- Panacea, FL (71)
- Panama City Beach, FL (1)
- Quincy, FL (241)
- Quincy Historic District, FL (5)
- Saint George Island, FL (6)
- Saint Marks, FL (1)
- Saint Teresa, FL (16)
- Seffner, FL (1)
- Sopchoppy, FL (14)
- Tallahassee, FL (13239)
- Thomasville, GA (25)
- Virgie, KY (1)
- Whigham, GA (2)
Job Locations and Reviews
Technician was very friendly with pre and post review of her service. She called to inform me of ETA.
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Indoor Unit (Air Handler in Attic): Unit services the East Side. Filter (20x25x5) was washed today. It is a washable type. Indoor coil condition is fair. Outdoor Unit (Heat Pump on Side of House): Outdoor coil condition is fair. Electrical Components (Tested and Working): Blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, compressor start capacitor, and contactor. Electrical wiring is working properly. Components Inspected (Good Condition): Blower wheel, secondary drain pan, primary drain pan, electrical wires secured, and ductwork. Measurements: Return air temperature: 70.0 Degrees Fahrenheit. Supply air temperature: 121.8 Degrees Fahrenheit. Condensate Drain System: Cleared drain line and tested safety switch. Drain line is strapped. Other Actions: Restored power to the units. Tested operations of the thermostat. Today I arrived on s
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Indoor Unit (Package Unit): Unit condition: Fair. Filter: Type: Antimicrobial, 10x16x1. Checked today. Indoor coil: Condition: Fair. Brush cleaned today. Outdoor Unit (Package Unit): Unit condition: Fair. Electrical Components: Tested and inspected: Blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring. All are working properly within manufacturer's specifications. System Components: Inspected: Blower wheel, primary drain pan, electrical wires secured, and ductwork. All are in good condition and working properly. Temperature Readings: Return air temperature: 67.0°F. Supply air temperature: 93.2°F. Condensate Drain System: Cleared drain line. Tested safety switch. Cleaned out primary pan. Drain line is strapped. Other: Checked batteries in the thermostat. Tested thermostat o
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Indoor Unit (Package Unit): Verified the unit is a package unit. Checked the filtration for the whole home system. Observed the filter size is 16x20x1. Brush cleaned the indoor coil, which was in fair condition. Outdoor Unit (Package Unit): Verified the unit is a package unit, located on the side of the house. Observed the outdoor coil is in fair condition. Electrical Components (Tested and Working): Verified proper operation and amperage within manufacturer's specifications for: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Blower Run Capacitor Fan Run Capacitor Compressor Start Capacitor Compressor Run Capacitor Contactor Electrical Wiring System Components (Inspected and Working): Verified the following components are in good condition and working properly: Blower Wheel Primary Drain Pan Electrical Wires Secured Ductwork System Readings: Return air temperature: 75.0 Degrees Fahr
tiara was great to work with. Pleasant lady.
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Checked the 20x20x1 pleated 1" filter; condition is fair. * Observed the indoor coil to be in fair condition. **Outdoor Unit (Heat Pump):** * Observed the outdoor coil to be in fair condition. * Tested and inspected the following electrical components, all operating within manufacturer's specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring * Inspected the following components, all found to be in good working order: * Secondary Drain Pan * Primary Drain Pan * Electrical Wires Secured * Ductwork **System Performance:** * Return air temperature: 72.0°F. * Supply air temperature: 116.0°F. * Tested safety switch an
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Here's a summary of the work completed: **Air Handler (Indoor Unit)** * Replaced the pleated 16x20x4" air filter. * Confirmed the indoor coil is in good condition. * Verified blower motor, heat strip kit, blower run capacitor are working within specifications. * Confirmed primary and secondary drain pans, and electrical wires are secured and in good condition. **Condenser (Outdoor Unit)** * Verified condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, compressor start capacitor, and defrost control board are working within specifications. * Cleared the condensate drain line. **System Performance** * Measured a return air temperature of 72.0°F and a supply air temperature of 162.0°F. * Tested thermostat operation and restored power to the units. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-02D2BE0C38554A08A
Today I arrived on site to perform a winter time maintenance on your HVAC equipment. **Indoor Unit (Furnace):** * Located in the closet, servicing the whole home. * Checked the Respicare filter (20x20x1). * Verified blower motor and inducer draft motor are working within specifications. * Confirmed blower wheel, burners, exhaust flue, heat exchanger, electrical wires, and ductwork are in good condition. **Outdoor Unit (Straight Cool):** * Located on the side of the house. * Observed the outdoor coil is in fair condition. **System Performance:** * Measured carbon monoxide levels at 0.00 PPM. * Recorded return air temperature at 70.0°F and supply air temperature at 126.0°F. * Cleared the condensate drain line and tested the safety switch. * Confirmed the drain line is strapped. * Tested thermostat operations and restored power to the units. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-A243-8EC9EC7061D34286B26460E59D0E47B9
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Closet):** * Verified the unit services the whole home. * Checked the pleated 1" filter (20x20x1); customer will provide their own filters. * Observed the indoor coil to be in fair and clean condition. **Outdoor Unit (Heat Pump in Back Yard):** * Observed the outdoor coil to be in fair and clean condition. * Tested and inspected the blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring; all are working properly within manufacturer's specifications. * Inspected the blower wheel, primary drain pan, and secured electrical wires; all are in good condition and working properly. **System Performance:** * Recorded a return air temperature of 78.0°F and a supply air temperature of 100.0°F. * Cleared the condensate drain line, cleaned out the primary pan, and tested the s
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Crawl Space/Attic):** * Observed the indoor coil to be in fair and clean condition. * Replaced the pleated 1" filter (size 20x20x1) with a spare provided by the customer. **Outdoor Unit (Heat Pump on Side of House):** * Observed the outdoor coil to be in fair and clean condition. * Tested and inspected the following electrical components, all working within manufacturer's specifications: blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. * Inspected the blower wheel, primary drain pan, secured electrical wires, and ductwork, all found to be in good working condition. **System Performance:** * Measured a return air temperature of 73 and 81°F and a supply air temperature of 91 and 122°F. * Cleared the condensate drain line, cleaned out the primary pan, and tested
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Attic):** * Checked the pleated 1" filter (14x24x1) and found it in fair condition. * Confirmed the indoor coil was clean and in fair condition. **Outdoor Unit (Heat Pump in Back Yard):** * Verified the outdoor coil was clean and in fair condition. * Tested and inspected the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, electrical wiring, and heat strip kit; all operating within manufacturer's specifications. * Confirmed the blower wheel, primary drain pan, electrical wires, and ductwork are in good condition and working properly. **System Checks:** * Measured a return air temperature of 81.0°F and a supply air temperature of 106.0°F. * Cleared the condensate drain line, cleaned out the primary pan, and tested the safety switch. * Confirmed the drain line is strapped. **Additional Actions:**
01/05/2025- I arrived on site to preform the wintertime maintenance visit for this location. The only issue I found was that unit #1 had a nearly clogged drain line that I have cleared with drain solve, before pulling out the blockage with a vacuum and verifying that it’s draining properly with a gallon of water and drain treatment solution. Both drain lines are now clear and draining properly at this time. All electrical components were found in spec and working properly. Both units are heating properly with a 30 degree and above temperature split. All air antimicrobial air filters have been replaced at the time of this visit. The customer has signed and approved of an estimate for some 25x25 antimicrobial air filter refills at this time. We will contact the customer when the filters are ready to be delivered and we will collect for them at that time. All equipment is functioning properly and heating properly at the time of service.
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit Service (Package Unit - Downstairs):** * Verified the unit is a package unit located downstairs. * Checked the pleated 1" filter (20x20x1) and found it in good condition. * Confirmed the indoor coil is clean and in good condition. **Outdoor Unit Service (Package Unit - Side of House):** * Verified the unit is a package unit located on the side of the house. * Confirmed the outdoor coil is clean and in good condition. **Electrical Component Testing:** * Tested and confirmed proper operation within manufacturer specifications for: * Blower Motor * Inducer Draft Motor * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring **Component Inspection:** * Inspected and confirmed good condition and proper operation of: * Blower Wheel * Burners * Exhau
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Located in the closet, servicing the whole home. * Checked the pleated 1" filter (18x18x1) and found it in good condition. * Confirmed the indoor coil is in good condition. **Outdoor Unit:** * Located on the side of the house. * Verified the outdoor coil is in good condition. **Electrical Components:** * Tested and confirmed proper operation of the blower motor, condenser fan motor, contactor, and electrical wiring within manufacturer specifications. **System Components:** * Inspected and verified the good condition and proper function of the blower wheel, secondary drain pan, primary drain pan, and secured electrical wires. **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary and secondary pans. * Tested the safety switch. **Temperature Readings:** * Return air temperature: 74.0°F. * Supply air temperat
Today I arrived on site and performed a winter time tune up on your system. The overall equipment condition is fair. **Indoor Unit:** * Located in the attic, servicing the whole home. * Checked the pleated 1" filter (20 x 20), condition is fair. * Indoor coil condition is fair. **Outdoor Unit:** * Located on the side of the house. * Outdoor coil condition is fair. **Electrical Components:** * Tested and inspected the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring; all are working properly within manufacturer's recommended specifications and amperages. **System Components:** * Inspected the blower wheel, secondary drain pan, primary drain pan, and electrical wires; all are in good condition and working properly. **System Readings:** * Return air temperature: 73.0 Degrees Fahrenheit. * Supply air temperature: 128.0 Degrees Fahrenheit.
Today I arrived on site and performed a winter time tune up on the system. Here's a breakdown of the work completed: **System Assessment:** * Overall equipment condition is fair. * Indoor unit is located in the closet. * Outdoor unit is located in the back yard. * The unit services the whole home. **Component Inspections & Testing:** * Checked the pleated 1" filter (18x18). Customer will replace it themselves. * Indoor and outdoor coils are in fair condition. * Verified proper operation of the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring. * Blower wheel, secondary drain pan, primary drain pan, and electrical wires are secured and in good condition. * Condensate drain line is strapped. **Maintenance Actions:** * Cleared the drain line. * Cleaned out the primary and secondary pans. * Tested the safety switch. * Dusted the thermo
Today I arrived on site and performed a winter time tune up on your system. Here's a summary of the work completed: * **System Overview:** * Overall equipment condition: Fair. * Area unit services: Whole Home. * **Indoor Unit:** * Location: Closet. * Filter: * Type: Washable, Pleated 2-6". * Size: 20x25. * Condition: Checked today. * Indoor Coil Condition: Fair. * **Outdoor Unit:** * Location: Side of House. * Outdoor Coil Condition: Fair. * **Electrical Components (Tested and Working):** * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Electrical Wiring * **Components Inspected (Good Condition):** * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires Secured * **Condensate Drain System:
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Here's a summary of the work completed: **Indoor Unit (Air Handler in Garage/Attic):** * Washed the 20x20x5 washable filter. * Confirmed the indoor coil is clean. * Inspected the blower motor and found it working within specifications. * Observed the blower wheel is in poor condition. * Inspected the primary and secondary drain pans and found them in good condition. **Outdoor Unit (Heat Pump in Back Yard):** * Confirmed the outdoor coil is clean. * Tested and inspected the condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring, and found them working within specifications. * Identified the heat strip kit is not working properly. **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary and secondary pans. * Tested the safety switch. * Confirme
Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Indoor Unit (Air Handler): Verified the air handler is located in the closet and services the whole home. Checked the washable 20x25x5 filter; it's in good condition. Confirmed the indoor coil is clean and in good condition. Outdoor Unit (Heat Pump): Verified the heat pump is located in the back yard. Confirmed the outdoor coil is clean and in good condition. Electrical Components: Tested and confirmed the blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring are working properly within manufacturer's specifications. System Components: Inspected and confirmed the blower wheel, primary drain pan, secondary drain pan, and electrical wires are secured and in good working condition. Measurements: Measured a return air temperature of 71.0°F and a supply air temperature of 103.2°F. Condensate Drain: Cleared the dr
As always, no complaints with Benson service. They are A1
Today I arrived on site and performed a winter tune-up. The system is currently working properly. **Indoor Unit (Air Handler):** * Verified the unit is located in the closet. * Confirmed the overall condition of the unit is good. * Checked the pleated 1" filter (20x24x1). * Customer has spare filters and will replace it themselves. * Confirmed the indoor coil is in good condition. **Outdoor Unit (Heat Pump):** * Verified the unit is located in the back yard. * Confirmed the outdoor coil is in good condition. **Electrical Components:** * Tested and inspected the following components, all working within manufacturer's specifications: * Blower Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring **System Components:** * Inspected the following components, all in good condition and working properly: * Blower Wheel *
Today I arrived on site and performed a winter tune-up on your system. Here's a summary of the work completed: Indoor Units (Air Handlers are in Attic): Replaced the pleated 1" filters: upstairs (size 16x20), downstairs (size 12x12, 16x20). Confirmed the indoor coils are clean and in fair condition. Outdoor Units (Heat Pumps on the Side of House): Verified the outdoor coils are clean and in good condition. Tested and inspected the following electrical components, confirming they are working within manufacturer's specifications: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Defrost Control Board Electrical Wiring Inspected the following components, confirming they are in good condition and working properly: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires Secured System Performance: Return air temperature measured at 66/67.0°F. Supply air temperature measured at 115/112.0°F. Condensate Drain Syste
I performed a winter time tune up on a Payne Heat pump unit View visual findings from this job here - https://visionshare.xoi.io/?id=XA-66B5-2F0ADA894681465492DA12EBF18431CD
Today I performed a wintertime tune up on your Carrier Heat-pump, your system is working properly at this time. Quincy Fl View findings from today’s job here - https://visionshare.xoi.io/?id=XA-D26D-A776D153BF194A079A2ED4FBDD8B215C
jov
Today I arrived on site and performed a winter tune-up. The system is currently working properly. **Indoor Unit (Air Handler):** * Confirmed the air handler is located in the closet and services the whole home. * Checked the 20x20x1 pleated 1" filter. * Observed the indoor coil is in poor and dirty condition; recommended a duct cleaning. **Outdoor Unit (Heat Pump):** * Verified the heat pump is located on the side of the house. * Confirmed the outdoor coil is in good and clean condition. **Electrical Components:** * Tested and confirmed the following components are working properly within manufacturer specifications: blower motor, heat strip kit, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, defrost control board, and electrical wiring. **System Components:** * Inspected and confirmed the following components are in good condition and working properly: blower wheel, ductwork, electrical wires secured
Today I arrived on site and performed the following maintenance: **Indoor Unit** * Confirmed the indoor unit condition is good and the coil is clean. * Noted the filter size is 18x18x1. * Checked the pleated 1" filter; the customer has spare filters and will replace it themselves. **Outdoor Unit** * Verified the outdoor unit condition is good. **Electrical Components** * Tested and confirmed the blower motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring are working within manufacturer specifications. **System Components** * Inspected and confirmed the blower wheel, heat exchanger, primary drain pan, and electrical wires are secured and in good condition. **Measurements & Adjustments** * Measured a return air temperature of 76.0°F and a supply air temperature of 107.2°F. * Cleared the condensate drain line and cleaned out the primary pan. **Additional Actions** * Dusted the thermostat and re
Today I arrived on site and performed a winter time tune up on your system. Here’s a summary of the work completed: **Indoor Unit (Mini Split, East Side):** * Checked the washable filter (12x6) and washed it. * Confirmed the indoor coil is in good condition. **Outdoor Unit (Heat Pump, Back Yard):** * Verified the outdoor coil is in good condition. **Electrical Components:** * Tested the blower motor, compressor, and electrical wiring; all are working within manufacturer's specifications. **System Components:** * Inspected the blower wheel, heat exchanger, primary drain pan, and secured electrical wires; all are in good condition. **Measurements:** * Measured a return air temperature of 78.0°F and a supply air temperature of 109.4°F. **Condensate Drain:** * Cleaned out the primary drain pan. * Confirmed the condensate drain line is connected and strapped. **Additional Actions:** * Dusted the thermostat. * Restored power to the units. * Tested the ther
Today I performed a wintertime tune up on your Lennox package unit and Mitsubishi mini-split, your systems are working properly at this time.Tallahassee Fl View findings from today’s job here - https://visionshare.xoi.io/?id=XA-D26D-F7328B383B284371A3D4790CE25E035C
Excelent
Great service all round. I had a migraine I was trying to sleep off and the tech took it consideration and didn’t make a noise while servicing the system.
Both Raymond and Aiden were exemplary employees. Efficient and capable, respectful of our home and property. You should be proud to have them in your employ.
Service was great, from beginning to end
Technician was very good and thorough. Reached ductwork in a very tight area I doubted access under the house and I was pleased it was corrected .
Very thorough with scheduling, prompness, thorough explanation pre and post service. Appears to be knowledgeable and courteous. I hope he stay with the company. I would like for him to be the technician for both properties.
The service man was very knowledgeable of what he had to do and very respectful.
Lee provided excellent service.
Excellent service.
Phillip is always very thorough and friendly.
Technician was knowledgeable. He took the time to explain what he was doing. He took the time to show short videos to show what he was doing
Very nice and we were pleased
Great Representative for your company. Mr. Rangel was very pleasant and conducted himself with Professionalism while Performing and completing his job
I want to thank you for sending Hunter to service our unit. Hunter worked so hard to restore our unit. Sure, we went a few days without heat due to the cord had to be ordered. When Hunter got the cord, he came and stayed for many hours to make sure our heat was restored and working properly. He did an excellent job.
Lee was was very respectful with explanations on her pre and post Review. I prefer her service again as well at 32 Carpenter's road.
Lee is very thorough, hands-on and very efficient! 10 out of 10. Highly recommend.
Professional. Neat. Courteous Efficient. Informative.
Phillip always does a thorough job. He is very conscientious and provides useful information.
Benson always is on time and their customer service is outstanding.
Liam was knowledgeable & explained the services he provided.
Friendly, conscientious. He's welcome any time
