Greenville, FL Heating and Air Conditioning
Benson’s Heating & Air Conditioning has been providing air conditioning, heating and indoor air quality services to the residents of Greenville, FL and the surrounding areas since 1981! Call us for your installation, repair and maintenance needs on HVAC units. Our experience and service truly set us apart! Read our reviews and find out why your neighbors consider us to be their nearby heating and air company in Greenville, FL.
Recent Jobs and Reviews in Greenville, FL
Greenville, FL at a glance
Benson's Heating and Air Conditioning has completed 13 jobs in Greenville, FL between November 2023 and May 2026.
The 18 customer reviews shown here average 4.9 out of 5.
The most recent job was on May 4, 2026.
Benson's Heating and Air Conditioning has completed 2 jobs in Greenville, FL in the last 12 months. The first job there was in November 2013.
Our Local Reviews by City
- Alligator Point, FL (46)
- Altamonte Springs, FL (1)
- Attapulgus, GA (5)
- Bainbridge, GA (14)
- Boston, GA (6)
- Bristol, FL (9)
- Cairo, FL (1)
- Cairo, GA (14)
- Carrabelle, FL (27)
- Chattahoochee, FL (15)
- Climax, GA (5)
- Crawfordville, FL (238)
- Eastpoint, FL (7)
- Greenville, FL (18)
- Havana, FL (414)
- Lamont, FL (16)
- Lanark Village, FL (1)
- Madison, FL (16)
- Meigs, GA (2)
- Metcalf, GA (1)
- Midway, FL (42)
- Monticello, FL (326)
- Mount Pleasant, TN (1)
- Ochlockonee Bay, FL (3)
- Panacea, FL (73)
- Panama City Beach, FL (1)
- Quincy, FL (254)
- Quincy Historic District, FL (5)
- Saint George Island, FL (6)
- Saint Marks, FL (1)
- Saint Teresa, FL (16)
- Seffner, FL (1)
- Sopchoppy, FL (14)
- Tallahassee, FL (13951)
- Thomasville, GA (30)
- Virgie, KY (1)
- Whigham, GA (2)
Job Locations and Reviews
Today I arrived on site to perform a summer tune-up on your system. ### Indoor Unit Service * Located the Air Handler in the crawl space. * Washed the washable 20x25x5 filter. * Noted the indoor coil is in fair condition. * Checked the blower wheel and ductwork; they are in good condition. * Cleared the condensate drain line, cleaned the primary and secondary drain pans, and tested the safety switch. * Confirmed the drain line is strapped. ### Outdoor Unit Service * Located the Heat Pump on the side of the house. * Cleaned the outdoor coil, which is in good condition. ### Electrical Component Checks * Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, blower run capacitor, contactor, defrost control board, and electrical wiring. * Found the compressor run capacitor and condenser fan motor run capacitor were not within manufacturer specifications. * Replaced the warranty capacitor. ### System Operations * Tested the th
Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Package Unit, Downstairs):** * Noted the unit is in fair condition. * Observed the indoor coil is in fair condition and clean. * Confirmed the customer has spare filters and will replace them. **Outdoor Unit (Package Unit, Back Yard):** * Noted the unit is in fair condition. * Observed the outdoor coil is in fair condition and clean. **Electrical Components:** * Tested and confirmed the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring are working properly within manufacturer's specifications. **Component Inspection:** * Inspected and confirmed the blower wheel, secondary drain pan, primary drain pan, electrical wires are secured, and ductwork are in good condition and working properly. **System Testing & Maintenance:** * Measured a ret
Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Package Unit):** * Verified the units service downstairs and upstairs. * Confirmed the indoor coil is in fair and clean condition. * Noted filter sizes are 18x18x1, 10x10x1, 12x20x1, and 14x14x1. * Observed pleated 1" filtration; customer will replace filters. **Outdoor Unit (Package Unit):** * Verified the outdoor coil is in fair and clean condition. **Electrical Components:** * Tested and confirmed proper operation of: Blower Motor, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, and Electrical Wiring. **System Components:** * Inspected and verified good condition of: Blower Wheel, Secondary Drain Pan, Primary Drain Pan, Electrical Wires Secured, and Ductwork. **Measurements:** * Measured return air temperature at 75°F downstairs and 76°F upstairs. * Measured supply air temperature at 57°F dow
Today I arrived on site and performed a summer tune-up on your system. Here's a summary of the work completed: **Indoor Unit (Air Handler in Crawl Space):** * Washed the 20x25 washable filter. * Brush cleaned the indoor coil. **Outdoor Unit (Heat Pump on Side of House):** * Cleaned the outdoor coil. **Electrical Components (Tested and Working):** * Verified proper operation of blower motor, inducer draft motor, heat strip kit, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, electrical wiring, and contactor. **System Components (Inspected and Working):** * Confirmed good condition of blower wheel, primary drain pan, secondary drain pan, and secured electrical wires. **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary and secondary pans. * Tested the safety switch. **Additional Actions:** * Dusted the return grills and thermostat. * Replaced the batteries in the thermostat. *
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the attic, identified as an air handler. * Services the whole home. * Washable filter, cleaned today, size 20x20. * Indoor coil is in good condition, brush cleaned today. Outdoor Unit Details: * Located on the side of the house, identified as a heat pump. * Outdoor coil is in good condition, cleaned today. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring System Inspection: * Inspected components in good condition: * Blower Wheel * Primary Drain Pan * Secondary Drain Pan * Electrical Wires secured * No components
Today, I arrived on site to perform winter maintenance on your HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the crawl space, identified as an air handler. * Services the whole home effectively. * Washable filter, cleaned today, size 20x25. * Indoor coil is in good condition, brush cleaned today. Outdoor Unit Details: * Positioned on the side of the house, identified as a heat pump. * Outdoor coil is in good condition and cleaned today. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring System Inspection: * Inspected components in good condition: * Blower Wheel * Primary Drain Pan * Secondary Drain Pan * Electrical Wires
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Package Unit - Area Unit Services: Main floor/upstairs - Filtration: Pleated 1", checked today - Customer says he replaces it regularly - Filter Sizes: 18x18x1, 10x10x1, 12x20x1, 14x14x1 - Condition of Indoor Coil: Good, clean Outdoor Unit: - Location: Back Yard, Package Unit - Condition of Outdoor Coil: Good, clean Electrical Components (Working Properly): - Blower Motor - Condenser Fan Motor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring Electrical Components (Not Working Properly): - Compressor Run Capacitor - Condenser Fan Motor Run Capacitor Other Inspected Components (Good Condition and Working Properly): - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - Secondary Drain Pan Tested for Carbon Monoxide:
Excellent service in every aspect!
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: - Fair Location, Type, and Picture of Indoor Unit: - Crawl Space - Air Handler Area Unit Services: - Whole house Filtration: - Washable - Filter was washed today Filter Size and Picture of filter: - 20x25x1 Condition of Indoor Coil: - Good - Indoor coil was brush cleaned today Location, Type, and Picture of Outdoor Unit: - Side of House - Heat Pump Condition of Outdoor Coil: - Good - Outdoor coil was cleaned today Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Contactor - Compressor Run Capacitor - Fan Run Capacitor - Electrical Wiring - Condenser Fan Motor - Compressor Inspected these components on your system and they are in good condition and working properly at this time: - Blower Wheel - Prima
Today I replaced your systems indoor control board under warranty . I verified all wiring is correct and the system is now operating properly. Tallahassee Fl
Upon setting thermostat to cool only outdoor unit come on and lineset immediately started freeezing. After further inspection found indoor control board blank but receiving power. I then tested the blower motor and other electrical components which came back fine. Bypassed with board with ecm tester to keep customer cooling over the weekend. Will reach out to manufacturer for replacement board. Paid via card. Thank you for your business.
I performed a winter time tune up on two Daikin Heat Pump Package units View visual findings from this job here - https://visionshare.xoi.io/?id=XA-981C-4E96029956A746EB9CD4ABBC5ECB3D2A
Today I performed a wintertime tuneup on your Bensons and AirEase air conditioning units in Greenville. Everything is working properly at this time. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-2621-BDBF2C57BB4342438749B2F9F72760C0
Cody arrived on time and we discussed the issues we have recently had and his immediately went to work. He was pleasant and thorough. Thanks Benson, for sending competent and excellent technicians out to take care of your customers!
Today I preformed a winter time maintenance on your Bensons heat pump in Greenville, Florida everything is working properly at this time View visual findings from this job here - https://visionshare.xoi.io/?id=XA-6E7D-687FA8F1672940B0A10BA1C65F5A91C1
Jeremiah called ahead of time and told us when he would arrive. He was efficient and thorough and explained everything he did. We are very pleased with his service.
they always do a great job. keeping my equipment in top condition.
We thank you for sharing your positive experience. It made our day.
He was on time and did a good job servicing my AC unit.
great job. thanks for such good service
I am always pleased with the service I get for Bensons. The people who come here are always professional. Keep up the good work
good job
Great service. TJ was all about getting it all checked out. Great job
nice you man and seemed to like what he was doing.
As always top notch service
He was very pleasant and went the extra mile to make sure we got the attention we paid for.
Excellent service!
Great Service
Great service, very knowledgeable service tech.
Did a good job and was pleased with his service.
We have always received great service from Benson's and have been a customer for 19 years.
Brandon Graham did a great job. Plus, he is very polite. All the workers that are sent here are very nice and do a great job.