Need Financing? Maintenance Plan Book Service Call Us!

Crawfordville, FL HVAC Company

Superior HVAC Services In Crawfordville, FL

For top-notch heating and air conditioning services in Crawfordville, FL, look no further than Benson’s HVAC. Our skilled team is devoted to maintaining your home’s comfort year-round, focusing on both performance and energy efficiency.

Need swift, dependable HVAC assistance? Dial 850-562-3132 or message us online to book an appointment today.

Cooling Solutions To Combat Florida’s Sweltering Summers

Florida’s intense heat calls for robust air conditioning. Our experts ensure your system can handle even the hottest days.

Dependable Heating For Chilly Evenings

While Crawfordville winters are mild, a reliable heating system is crucial for those cool nights. Our heating services keep your home snug and warm.

Enhance Your Indoor Air Quality

The air you breathe inside your home is just as important as its temperature. Benson’s indoor air quality solutions help you maintain a healthier living environment.

Heat Pump Services For All-Season Comfort

In Florida’s mild climate, heat pumps offer an efficient solution for both heating and cooling.

Ductless Mini-Splits For Precision Climate Control

Want targeted heating and cooling in specific areas? Ductless mini-splits offer precise temperature control in any room of your home.

Custom Solutions For Businesses

At Benson’s HVAC, we also specialize in commercial HVAC systems designed to maintain comfort in your business while minimizing energy costs.

Why Choose Benson’s In Crawfordville

Ready For Year-Round Comfort? Reach Out To Benson’s HVAC Today!

Whatever the season, Benson’s HVAC is here to ensure your Crawfordville, FL home or business maintains optimal comfort with our premium heating and air conditioning services. Check out our reviews here on our website or on Google to see what your friends and neighbors have to say about us. Then, give us a call at 850-562-3132 or drop us a message online to schedule your service. Our team stands ready to deliver the reliable HVAC solutions you need for comfort in every season.

Recent Jobs and Reviews in Crawfordville, FL

Rated 4.9 out of 5 stars based on 206 customer reviews

Customers say: The overall sentiment of the reviews is positive, with a slight inclination towards neutrality. The positive reviews highlight the exceptional customer service, prompt and efficient service, professional and knowledgeable technicians, and overall satisfaction with the services provided by Benson's Heating and Air Conditioning. The negative reviews mainly focus on issues such as cancelled appointments, long wait times, and minor inconveniences during the service process. However, the positive reviews outweigh the negative ones, indicating that the majority of customers have had positive experiences with Benson's services.

Job Locations and Reviews

Bryce D.
Bryce D. Checked in
Today I arrived on site and performed a summer tune-up on the system. Here's a summary of the work completed: **Indoor Unit (Air Handler in Closet):** * Verified the unit services the whole home. * Checked the pleated 1" filter (20x20x1). Customer will provide their own filters. * Confirmed the indoor coil is clean. **Outdoor Unit (Heat Pump on Side of House):** * Confirmed the outdoor coil is clean. **Electrical Components:** * Tested and verified proper operation of the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. **System Components (Good Condition):** * Inspected and confirmed the blower wheel, primary drain pan, and electrical wires are secured. **System Performance:** * Measured a return air temperature of 77.0°F and a supply air temperature of 58.0°F. * Cleared the condensate drain line, cleaned out the primary pan, and tested the safety switch. **Additional Actions:** *
Crawfordville, FL 32327
Bryce D.
Bryce D. Checked in
Today I arrived on site and performed a summer tune-up on your system. Here's a summary of the work completed: **Indoor Unit (Air Handler in Attic):** * Replaced the 20x20x5 pleated filter. * Confirmed the indoor coil is clean and in fair condition. **Outdoor Unit (Heat Pump on Side of House):** * Verified the outdoor coil is clean and in fair condition. * Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. **System Components:** * Inspected and confirmed the blower wheel, primary drain pan, electrical wires, and ductwork are in good working order. * Cleared the condensate drain line and cleaned out the primary pan. * Tested the safety switch. **Measurements & Adjustments:** * Measured a return air temperature of 76.0°F and a supply air temperature of 55.0°F. **Additional Actions:** * Dusted the thermostat. * Checked the thermostat batteri
Crawfordville, FL 32327
Jeremy  B.
Jeremy B. Checked in
Upon arrival, I found the customers three communicating thermostats, not communicating with the outdoor air temp sensor. I also found one of the damper actuators not closing the damper all the way for the upstairs bedroom. I was able to adjust the damper actuator and get the damper working properly. I reprogrammed/reconnected all three thermostats to the outdoor sensor. I disassemble the outdoor sensor and found where the batteries snap in the metal prongs, holding the batteries in were extremely loose and the batteries were coming out. The sensor was also mounted on a door which got opened and closed periodically. After adjusting the battery prongs on the sensor and relocating the sensor. All three thermostats were reconnected and everything is on and working properly at this time. .
Crawfordville, FL 32327
Lee C.
Lee C. Checked in
Today I arrived on site and performed a summer tune-up on the system. Indoor Unit (Air Handler - Attic): Checked the pleated 1" filter (20X20X1), recently changed this week. Verified the indoor coil is in good, clean condition. Outdoor Unit (Heat Pump - Back Yard): Cleaned the outdoor coil, which was already in good condition. Electrical Components: Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. System Components: Inspected and confirmed the blower wheel, secondary drain pan, primary drain pan, and electrical wires are secured and in good working order. Measurements & Adjustments: Measured a return air temperature of 70.0°F and a supply air temperature of 53.0°F. Cleared the condensate drain line, cleaned out the primary pan, and tested the safety switch. Additional Actions: Dusted the return grills and thermostat. Restored power to the
Crawfordville, FL 32327
Ej O.
Ej O. Checked in
Diagnostic, found outdoor unit to not be turning on and the dual run capacitor swollen and no longer working. I replaced the failed dual run capacitor with a new turbo 200 capacitor and the system turned on checked component amperage’s and everything is reading within manufacture specifications . The system is now cooling properly.
Crawfordville, FL 32327
Liam S.
Liam S. Checked in
Today I arrived on site to perform routine maintenance on your home's HVAC system. **Indoor Unit (Air Handler):** * Verified the air handler is located in the closet and services the whole home. * Checked the pleated 1" filter (20x20) and found it in good condition. * Cleaned the indoor coil with a brush. **Outdoor Unit (Heat Pump):** * Confirmed the heat pump is located on the side of the house. * Cleaned the outdoor coil. **Electrical Components:** * Tested and confirmed the following components are working within manufacturer's specifications: blower motor, inducer draft motor, heat strip kit, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, electrical wiring, and contactor. **System Components:** * Inspected and verified the following components are in good working condition: blower wheel, primary drain pan, secondary drain pan, and electrical wires. **Condensate Drain System:** * Cleared the drain line. * Cl
Crawfordville, FL 32327
Liam S.
Liam S. Checked in
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Attic, Garage - Type: Air Handler - Picture: Available Area Unit Services: - Whole house Filtration: - Respicare - Checked today Filter: - Size: 23x20 - Picture: Available Indoor Coil: - Condition: Good, Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: Available Outdoor Coil: - Condition: Good, Clean - Cleaned today Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Compressor Start Capacitor - Contactor - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Secondary Drain Pan - Electrical Wires Secured - Primary Drain Pan Tested for Carbon Monoxide: - N/A Return Air Temperature: - 69.2 Degrees Fahrenheit Supply Air Temperature: - 49.1 Degrees Fa
Crawfordville, FL 32327
Jeremy  B.
Jeremy B. Checked in
Upon arrival, I found the customers Daikin mini split not cooling properly due to a low refrigerant charge. The system was almost completely out of refrigerant. It holds a little over 2 pounds. I sent an estimate for 2 pounds. The estimate was approved. After adding 2 pounds of refrigerant the system started cooling properly . I then performed an electronic leak search. But the wind and rain was so bad outside. My leak detector was trying to hit outside in the condenser, but I will have to do a follow up and return when the weather is better so I can be positive. We will call to schedule a follow up. The customer is also interested in prices on a new mini split. Your system is cooling properly at this time. There is no guarantee to how long the refrigerant will last.
Crawfordville, FL 32327
Aj S.
Aj S. Checked in
Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Located in the attic/garage. * Verified the overall equipment condition as good. * Checked the pleated 1" filter (size 20x20x1). * Observed the indoor coil in fair condition. **Outdoor Unit (Heat Pump):** * Located on the side of the house. * Determined the outdoor coil to be in good condition and cleaned it. **Electrical Components:** * Tested and confirmed proper operation within manufacturer specifications for: * Blower Motor * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring **System Components:** * Inspected and verified good working condition of: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires Secured * Ductwork **Condensate Drain System:** * Cleared the drain line. * Cle
Crawfordville, FL 32327
Aj S.
Aj S. Checked in
Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Attic):** * Checked the pleated 20x20x4 air filter; recommend replacing it. * Inspected the indoor coil; recommend a duct cleaning due to its fair condition. **Outdoor Unit (Heat Pump on Side of House):** * Cleaned the outdoor coil, which was in fair condition. * Tested and confirmed proper operation of the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. **System-Wide Checks:** * Confirmed the blower wheel, secondary drain pan, primary drain pan, electrical wires, and ductwork are in good working order. * Cleared the condensate drain line, cleaned out the secondary and primary pans, and tested the safety switch. * Measured a return air temperature of 78.0°F and a supply air temperature of 59.7°F. * Dusted the return grills and restored power to the units. * Tested therm
Crawfordville, FL 32327
Aj S.
Aj S. Checked in
Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Equipment Overview:** * The overall equipment condition is fair. * The indoor unit is a package unit located inside. * The outdoor unit is a package unit located on the side of the house. **Coil Maintenance:** * The indoor coil is in fair condition. * The outdoor coil is in fair condition and was cleaned today. **Electrical Component Testing:** * Verified proper operation of the blower motor, compressor, condenser fan motor, compressor run capacitor, fan run capacitor, contactor, electrical wiring, and blower run capacitor. **Component Inspection:** * Confirmed the blower wheel, secured electrical wires, ductwork, secondary drain pan, and primary drain pan are in good working order. **System Readings & Adjustments:** * The return air temperature was measured at 76.0°F, and the supply air temperature was 55.0°F. * The condensate drain line was cleared, and both the prima
Crawfordville, FL 32327
Brandon J.
Brandon J. Checked in
I performed a tune up on the equipment. Testing system operations, component amperages, capacitor ratings, cleared the drain line, checked the filters, cleaned the condenser outside, and checked the batteries in the thermostat. The system is working properly at this time.
Crawfordville, FL 32327
Review
This was a return visit for Aidan. He is very professional and clearly explained each step as it was done. I hope that you will continue to support his career.
LAWHON - Crawfordville, FL 32327
Aidan D.
Aidan D. Checked in
Today I arrived on site and performed a summer tune-up on the whole home package unit. **Indoor Unit Service:** * Confirmed the indoor unit is a package unit. * Verified the indoor coil is clean and in good condition. * Checked the pleated 1" filter; the customer has spare filters and will replace them. * The filter size is (2) 10x20x1. **Outdoor Unit Service:** * Confirmed the outdoor unit is a package unit located on the side of the house. * Verified the outdoor coil is clean and in good condition. **Electrical Component Testing:** * Tested and confirmed the following components are working within manufacturer specifications: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring **Component Inspection:** * Inspected and confirmed the following components are in good working order:
Crawfordville, FL 32327
Aidan D.
Aidan D. Checked in
Today I arrived on site and completed the following maintenance: **Indoor Unit (Air Handler - Garage, Attic):** * Verified the unit is servicing the whole home. * Checked and replaced the 20x25x5 pleated filter. * Customer requested additional filters for a charge. * Confirmed the indoor coil is clean and in good condition. **Outdoor Unit (Heat Pump - Side of House):** * Verified the outdoor coil is clean and in good condition. * Cleaned the outdoor coil. **Electrical Components:** * Tested and confirmed proper operation of: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring **System Components:** * Inspected and confirmed good condition and proper operation of: * Blower Wheel * Ductwork * Electrical Wires Secured * Primary Drain Pan * Secondary Dra
Crawfordville, FL 32327
Aidan D.
Aidan D. Checked in
Today I arrived on site and performed a summer tune-up on the system. The overall equipment condition is good. **Indoor Unit (Air Handler in Attic):** * Verified the indoor coil is clean and in good condition. * Confirmed the pleated 20x20x5 air filter is checked. * Noted the customer will replace the filter themselves. **Outdoor Unit (Heat Pump on Side of House):** * Verified the outdoor coil is clean and in good condition. **Electrical Components (Tested and Working):** * Confirmed proper operation and amperage of: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring **System Components (Inspected and Working):** * Verified the condition and operation of: * Blower Wheel * Ductwork * Electrical Wires Secured * Primary Drain Pan * Secondary Drain Pan **Conde
Crawfordville, FL 32327
Aidan D.
Aidan D. Checked in
Today I arrived on site and performed a summer tune-up on the system. Here's a summary of the work completed: **System Inspection & Maintenance:** * Verified the overall equipment condition as good. * Serviced the units covering the East and West sides of the house. * Confirmed the indoor unit is an air handler located in the garage attic. * Confirmed the outdoor unit is a heat pump located on the side of the house. **Component Checks & Services:** * Indoor coil condition: Good and clean. * Outdoor coil condition: Good and clean. * Cleared the drain line. * Cleaned out the primary and secondary drain pans. * Tested the safety switch. **Electrical Components:** * Tested and inspected the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, defrost control board, and electrical wiring; all are working properly within manufacturer's specifications. **Component Condition:** * Inspected the
Crawfordville, FL 32327
Bryce D.
Bryce D. Checked in
Today, I arrived on site to perform maintenance on the HVAC equipment. Overall Equipment Condition: * Fair Indoor Unit Details: * Location: Garage, Attic * Type: Air Handler * Filtration: Pleated 2-6", replaced with customer's spare filters * Filter Size: 20x25x4 * Indoor Coil Condition: Fair, Clean Outdoor Unit Details: * Location: Side of House * Type: Heat Pump * Outdoor Coil Condition: Fair, Clean Electrical Components: * Tested and inspected components: Blower Motor, Compressor, Condenser Fan Motor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Electrical Wiring * All components are working properly within manufacturer's recommended specs Inspected Components: * Good condition: Blower Wheel, Primary Drain Pan, Electrical Wires Secured * Poor condition: N/A Testing Results: * Return Air Temperature: 76.0 Degrees Fahrenheit * Supply Air Temperature: 62.7 Degrees Fahrenheit * Cleared Drain Line, Cleaned Out Primary Pan, Tested Safety Switch Additional Notes: * Dusted
Crawfordville, FL 32327
Review
Great Company
Olds - Crawfordville, FL 32327
Justin W.
Justin W. Checked in
Crawfordville, FL 32327
Aidan D.
Aidan D. Checked in
Today, I arrived on site to perform a summer tune-up on the HVAC system. Indoor Unit: * Location: Closet * Type: Air Handler * Condition: Good * Filtration: * Size: 20x20x1 * Status: Checked and replaced today using customer-provided spare filters * Picture: Attached Outdoor Unit: * Location: Side of House * Type: Heat Pump * Condition: Good * Coil Status: Cleaned today * Picture: Attached Component Testing: * Electrical Components Tested: * Blower Motor: Working properly * Condenser Fan Motor: Working properly * Compressor: Working properly * Blower Run Capacitor: Working properly * Compressor Run Capacitor: Working properly * Fan Run Capacitor: Working properly * Contactor: Working properly * Defrost Control Board: Working properly * Electrical Wiring: Working properly * No issues found with tested components Inspections: * Components in good condition: * Blower Wheel * Ductwork * Electrical Wires Secured * Primary Drain Pan * No components in po
Crawfordville, FL 32327
Aidan D.
Aidan D. Checked in
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Condition rated as fair. Indoor Unit Details: * Located in a closet. * Services the whole home. * Filtration system: Respicare. * Customer will provide their own filters for replacement. Indoor Coil Condition: * Condition rated as fair. Outdoor Unit Details: * Located in the back yard. * Type: Straight Cool. * Condition rated as fair. Electrical Component Status: * Tested and inspected components working properly: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring Component Inspection: * Good condition and working properly: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires secured * No components found in poor condition. Temperature Readings: * Return Air Temperature: 76.0 degrees Fahrenheit. * Supply Air Temperature: 56.0 degrees Fahrenheit. Condensate Drain S
Crawfordville, FL 32327
Aidan D.
Aidan D. Checked in
Today, I arrived on site to perform a summer time tune-up on the HVAC system. Overall Equipment Condition: * Good condition observed throughout the system. Indoor Unit Inspection: * Location: Garage Attic Air Handler * Services: Whole Home * Filtration: Pleated 2-6", replaced today * Filter Size: 20x20x4 * Indoor Coil: Good and clean condition Outdoor Unit Inspection: * Location: Side of House (Heat Pump) * Outdoor Coil: Good and clean; cleaned today Electrical Components Tested: * All components are functioning properly: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring Condition of Other Components: * Blower Wheel, Ductwork, Electrical Wires, Primary Drain Pan, and Secondary Drain Pan are in good condition Temperature Readings: * Return Air Temperature: 75.0°F * Supply Air Temperature: 52.0°F Condensate Drain System: * Cleared drain l
Crawfordville, FL 32327
Aidan D.
Aidan D. Checked in
Today, I arrived on site to perform a thorough inspection and maintenance of the HVAC system. Overall Equipment Condition: * Equipment is in good condition. Indoor Unit: * Located in the attic as an air handler. * Servicing the whole home. * Filtration system uses pleated 2-6" filters. * Replaced filters with customer-supplied spare filters today. * Filter size is 16x20x5. * Indoor coil is clean and in good condition. Outdoor Unit: * Positioned on the side of the house as a heat pump. * Outdoor coil is clean and in good condition; cleaned today. Electrical Components: * All tested components are functioning within manufacturer specifications: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Fan Run Capacitor * Compressor Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring * No issues found with electrical components. System Inspection: * Blower Wheel, ductwork, electrical wires secured, primary and secondary drain pans
Crawfordville, FL 32327
Review
Ray is great and I hope he is always our technician. He is so polite and respectful, he explains everything so well and has always done a wonderful job!
Turner - Crawfordville, FL 32327
Raymond P.
Raymond P. Checked in
Today I performed a summertime tuneup on your Goodman heat pump unit. Everything is working properly at this time. Thank you for your business. Crawfordville FL
Crawfordville, FL 32327
Review
Excellent as Always
THORNTON - Crawfordville, FL 32327
Sebastian C.
Sebastian C. Checked in
Today, I arrived on site to perform a summer tune-up on the HVAC system. Equipment Overview: * Overall equipment condition is fair. * Indoor unit located in the attic, servicing the whole home. * Filtration system was washed today; filter is washable, size 20x25x5. * Condition of the indoor coil is fair. Outdoor Unit: * Outdoor unit located in the backyard. * Condition of the outdoor coil is fair. Electrical Components Inspection: * Tested electrical components include: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Contactor * Electrical Wiring * Compressor Start Capacitor * All tested components are working properly within manufacturer’s recommended specs and amperage. Additional System Checks: * Inspected components in good condition: * Blower Wheel * Primary Drain Pan * Electrical wires secured * No components found in poor condition. Temperature Readings: * Return air temperature registered at 75.0 d
Crawfordville, FL 32327
Review
Thorough, professional, personable and polite
Smith - Crawfordville, FL 32327
Sebastian C.
Sebastian C. Checked in
Today, I arrived on site to perform a summer time tune-up on the HVAC system. Equipment Condition: * Overall equipment condition noted as fair. * Indoor unit located in the garage attic. * Outdoor unit positioned on the side of the house. Filtration: * Customer has spare filters; prefers to replace them independently. * Filter size identified as 20x20x1. Electrical Components: * All tested electrical components are functioning within manufacturer specs: * Blower Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring * No components were found to be malfunctioning or out of spec. System Inspection: * Indoor coil condition noted as fair. * Outdoor coil condition also assessed as fair. * Blower Wheel and Primary Drain Pan inspected and found in good condition. * Electrical wires were secured during the inspection. Temperature Readings: * Return air temperature recorded at 69.0 degrees Fahrenheit. * Supply
Crawfordville, FL 32327
Review
Fast and efficient. Pleasant guy to.
rick southerland - Crawfordville, FL 32327
Response from Benson's Heating and Air Conditioning:

Thank you for your feedback. Our team is very thankful.

Review
Great
Cortese - Crawfordville, FL 32327
Response from Benson's Heating and Air Conditioning:

Thank you so much for your amazing review! We will share this with the team to let them know to keep up the amazing work!

Review
The tech was very pleasant and knowledgable.
Dave Holman - Crawfordville, FL 32327
Review
GREAT SERVICE. GOOD PICS SHOWING CONDITION. PROFESSIONAL AND THOROUGH!
LENAERTS - Crawfordville, FL 32327
Review
Aiden was very polite and thorough in his explanations. He offered to replace the filter and cleaned around the the outside unit.
Perry - Crawfordville, FL 32327
Review
Great knowing within 5+- minutes when they will arrive.
Jim - Crawfordville, FL 32327
Review
Excellent work
BLAKE - Crawfordville, FL 32327
Review
Excellent service!
Mary - Crawfordville, FL 32327
Review
Aidan is very thorough and cordial in explaining all aspects of the service call.
Parr - Crawfordville, FL 32327
Review
Emonte was friendly, efficient, and knowledgeable. Learned a few things from him regarding our AC unit. Nice guy.
ARNOLD - Crawfordville, FL 32327
Review
AJ was fast, efficient, considerate, and fully explained the services be provided.
THORNTON - Crawfordville, FL 32327
Review
Great service
BUKLEY - Crawfordville, FL 32327
Review
Ray is polite, professional and very helpful with any question's.
Glunn - Crawfordville, FL 32327
Review
Very nice and friendly also professional. Thanks!
Rodriguez - Crawfordville, FL 32327
Review
Brenden provided very thorough service. He was extremely knowledgeable, efficient, and courteous in handling the Fall service for our HVAC. Brenden is an excellent asset for Benson’s.
AHLFELD - Crawfordville, FL 32327
Review
great job
REGISTER - Crawfordville, FL 32327
Review
excellent service
WEBER - Crawfordville, FL 32327
Review
Good job, Cody!
STAPLETON - Crawfordville, FL 32327
Review
Top notch as usual
Parr - Crawfordville, FL 32327
Review
AJ gave us excellent service and clearly explained the issue he found. He was able to resolve what had to be done and had the office set up the service call that will be needed.
LAWHON - Crawfordville, FL 32327
Review
Tech was on time, courteous, professional and informative.
Earl - Crawfordville, FL 32327
Review
Ran into a problem with our thermostat during routine maintenance that was beyond routine. Benson's responded right away; sending not only a replacement for the thermostat but also a supervisor to troubleshoot the problem with the thermostat. Required 2 1/2 hours to identify and correct the problem. We were really impressed with the way this problem was handled and resolved. Could not have asked for better, more professional, or quicker service. Most impressed with the supervisor's work, interaction with us, and attitude as he worked to track down the problem.
ARNOLD - Crawfordville, FL 32327

It’s Even Better With The App! Download Now:

Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request
*
Your Contact and Service Location
*
*
To Serve You Best
Have we served you in the past?
Yes
No
What Date Would You Like To Schedule Your Service?
What time of day is best for you?
First Available
Morning
Afternoon
By pressing Submit I agree to receive phone, email, or text messages from Benson's Heating and Air Conditioning to the provided mobile number and also agree to the Benson's Heating and Air Conditioning terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next