Panacea, FL HVAC Service

Panacea, FL Heating and Air Conditioning

Benson’s Heating & Air Conditioning has been providing air conditioning, heating and indoor air quality services to the residents of Panacea, FL and the surrounding areas since 1981! Call us for your installation, repair and maintenance needs on HVAC units.

Our experience and service truly set us apart! Read our reviews and find out why your neighbors consider us to be their nearby heating and air company in Panacea, FL.

Recent Jobs and Reviews in Panacea, FL

Rated 5.0 out of 5 stars based on 66 customer reviews

Customers say: The overall sentiment of the reviews is positive, with a slight inclination towards neutrality. The positive reviews highlight the exceptional customer service, prompt and efficient service, professional and knowledgeable technicians, and overall satisfaction with the services provided by Benson's Heating and Air Conditioning. The negative reviews mainly focus on issues such as cancelled appointments, long wait times, and minor inconveniences during the service process. However, the positive reviews outweigh the negative ones, indicating that the majority of customers have had positive experiences with Benson's services.

Job Locations and Reviews

Bryce D.
Bryce D. Checked in
Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Located in the closet and identified as an air handler. * Verified the unit services both the East and West sides of the building. * Checked the pleated 20x25x4 filter; it was in fair condition. * Confirmed the indoor coil was clean and in fair condition. **Outdoor Unit (Heat Pump):** * Located on the side of the house and identified as a heat pump. * Verified the outdoor coil was clean and in fair condition. * Tested and confirmed the proper operation of the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. * Inspected and confirmed the blower wheel, primary drain pan, and electrical wires were secured and in good condition. **System Performance:** * Measured a return air temperature of 77.0°F and a supply air temperature of 57.0°F. * Cleared the condensate drain li
Panacea, FL 32346
Jeremy  B.
Jeremy B. Checked in
Today I performed a routine maintenance on your heat pump split system. I checked all electrical connections on both indoor and outdoor equipment, checked the air filter, flushed the drain line, checked the capacitor ratings they tested the system operations before leaving. Your system is operating properly at this time .
Panacea, FL 32346
Lee C.
Lee C. Checked in
Today I arrived on site and performed a summer tune-up on the system. Here's a summary of the work completed: Indoor Unit (Air Handler): Located in closet; serviced for whole home. Replaced the 20x25x5 pleated filter. Cleaned the indoor coil, noted as in fair condition. Inspected blower wheel, primary drain pan, and electrical wires; all in good condition. Outdoor Unit (Heat Pump): Located on the second-floor north deck. Observed outdoor coil in poor condition, corroded due to salt air. Tested blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring; all operating within manufacturer specifications. System Performance: Return air temperature measured at 76.0°F. Supply air temperature measured at 54.0°F. Cleared the condensate drain line and cleaned out the primary pan. Tested the safety switch. Additional Actions: Dusted the thermostat. Restored power to the units. Tested thermostat operation.
Panacea, FL 32346
Jeremy  B.
Jeremy B. Checked in
Found evaporator coil leaking sent estimate for repairs 6/10/25 Today we replaced the evaporator coil and txv, pressure tested the system to 350psi for 20 minutes, pulled a deep vacuum under 500 microns and added refrigerant charge back to the unit to get it cooling properly. Tallahassee fl
Panacea, FL 32346
Review
Great job
MCNEILL - Panacea, FL 32346
Aj S.
Aj S. Checked in
Today I performed a Summertime Tuneup on your Goodman Heat pump and Daikin mini split. Great news is everything is working properly checked amperage is on outdoor condenser and indoor air handler. Everything was Amping out properly no loose or burnt wiring‘s. One thing I did notice was outdoor condenser contactor was a little pitted, will send over estimate for one pole contactor on outdoor unit did not perform deep clean Minisplit on blower wheel and coil, due to blower wheel and coil being very clean took apart fins and Minisplit head, wiped down everything on mini split indoor head to keep clean and also clear drain lines today. Thank you and have a great day. In St Teressa, FL
Panacea, FL 32346
Hunter C.
Hunter C. Checked in
06/03/2025- I arrived on site to find the core sense tripped, after resetting the core sense the unit came on without issue. However since this is a reoccurring issue I checked all possible causes for this intermittent tripping. I found the return duct heavily bent right at the return grill due to the location of the air handler and the tight attic. I positioned the duct the best I could to allow optimal airflow as well as changed the dirty air filter with one on location. I found the condenser coil to be fairly dirty as well, I have cleaned the condenser coil as well. Lastly I found the unit overcharged with refrigerant which lead to a 12-16 degree subcool. After pulling out 1 lb of 410a from the unit the subcool stabilized at 7-8 degrees, I then verified the temperature split of the unit which held at 19-20 degrees. I believe that the airflow issue’s compounded the fact that the unit was overcharged with refrigerant, leading to the intermittent tripping on the core sense. However I h
Panacea, FL 32346
Jeremy  B.
Jeremy B. Checked in
Upon arrival, I found a customer’s straight, cool condenser with gas furnace that supplies the guest house above the garage, not cooling properly due to a low refrigerant charge, and the thermostat needing to be reprogrammed. I sent an estimate for a couple pounds of Freon and to reprogram the thermostat. After adding refrigerant, I reprogrammed the thermostat and tested the system operations. Your system is operating/cooling properly at this time however, I did find a severely rusted bi-Flo filter drier in the condenser. I Will get an estimate created to replace it. I would recommend replacing it ASAP
Panacea, FL 32346
Sebastian C.
Sebastian C. Checked in
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-F3DE-B1D039CFC9524B5DA1743DF1F48808A0 Today I arrived on site and performed a summer tune-up on the whole home system. Here's a summary of the work completed: **Filtration:** * Replaced the 20x20 filter using the customer's spare filters. **Coils:** * Observed the indoor coil in the attic to be in fair condition. * Observed the outdoor coil on the side of the building to be in fair condition. **Electrical Components (Tested & Working):** * Verified proper operation of the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring. **Components (Inspected & Condition Noted):** * Inspected the blower wheel, primary drain pan, and secondary drain pan and found them to be in poor condition and not working properly. * Secured electrical wires. **Condensate Drain System:** * Clea
Panacea, FL 32346
Lee C.
Lee C. Checked in
Performed a summer time tune up on the hvac equipment. Testing system operations, component amperage’s, capacitor ratings, cleared the drain line, changed the filter, tested the thermostat, and dusted the return grills. The system is working properly at this time. Billable
Panacea, FL 32346
Liam S.
Liam S. Checked in
Today I arrived on site and: * Observed the overall equipment condition as good. * Serviced the unit that services the upstairs and downstairs areas. * **Filtration:** * Replaced the pleated 1" filter (size 10x24). * **Indoor Unit (Air Handler in Attic Closet):** * Found the indoor coil in good condition and brush cleaned it. * **Outdoor Unit (Heat Pump on Side of House):** * Found the outdoor coil in good condition and cleaned it. * **Electrical Components (Tested and Working):** * Verified proper operation of the blower motor, inducer draft motor, heat strip kit, condenser fan motor, and compressor. * Confirmed blower run capacitor, compressor run capacitor, fan run capacitor, and contactor are within specifications. * Checked and confirmed electrical wiring is in good condition. * **Inspected Components (Good Condition):** * Verified the blower wheel, primary drain pan, secondary drain pan, and secured electrical wires are in
Panacea, FL 32346
Liam S.
Liam S. Checked in
Today I arrived on site: * **Indoor Unit (Attic Air Handler):** * Verified the air handler is in good condition. * Checked the pleated 1" filter (20x20). * Cleaned the indoor coil with a brush. * **Outdoor Unit (Heat Pump - Back of Building):** * Verified the heat pump is in good condition. * Cleaned the outdoor coil. * Tested and inspected the blower motor, inducer draft motor, heat strip kit, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring; all are working within manufacturer's specifications. * Inspected the blower wheel, primary drain pan, secondary drain pan, and secured electrical wires; all are in good condition. * **System Performance:** * Return air temperature: 75.0°F. * Supply air temperature: 52.6°F. * Cleared the condensate drain line. * Cleaned out the primary and secondary pans. * Tested the safety switch.
Panacea, FL 32346
Brenden N.
Brenden N. Checked in
Today I performed a routine maintenance on your HVAC equipment. I checked all electrical connections on both indoor and outdoor equipment, flushed your drain lines, washed your air filters, checked the capacitor ratings and rinsed the condensers outside. Both systems are operating properly at this time .
Panacea, FL 32346
Brenden N.
Brenden N. Checked in
Today I performed a maintenance/filter change on all your HVAC equipment. I changed all air filters, flushed the drain lines, check the tension on the belts, checked the capacitor ratings and made sure all systems were on and cooling properly before leaving. Your systems are operating properly at this time .
Panacea, FL 32346
Aidan D.
Aidan D. Checked in
Today, I arrived on site to perform a summer time tune-up on the HVAC system. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Location: Closet, Air Handler * Services: Whole home * Filtration: Pleated 1", size 20x20x1 * Customer will provide their own filters for replacement. * Indoor coil condition: Fair, clean. Outdoor Unit Details: * Location: Side of house, Heat Pump * Outdoor coil condition: Good, clean. Electrical Components: * Tested and found to be working properly: Blower Motor, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Defrost Control Board, Electrical Wiring. * No components failed testing. System Inspections: * Components in good condition: Blower Wheel, Ductwork, Electrical Wires Secured, Primary Drain Pan. * No components found in poor condition. Temperature Readings: * Return Air Temperature: 70.0 Degrees Fahrenheit * Supply Air Temper
Panacea, FL 32346
Liam S.
Liam S. Checked in
Today, I arrived on site to perform maintenance on the HVAC system. Here’s a summary of the work completed: Overall Equipment Condition: * Overall condition of the equipment is good. Indoor Unit: * Location: Air Handler in a closet. * Services the whole home. * Filtration: Replaced Respicare filter today (size 20x20). * Indoor coil: Good condition, clean, and brushed cleaned today. Outdoor Unit: * Location: Heat pump on the side of the house. * Outdoor coil: Good condition and cleaned today. Electrical Components: * Tested and inspected the following components, all working properly within manufacturer specs: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring System Inspection: * Inspected components in good condition: * Blower Wheel * Primary Drain Pan * Secondary Drain Pan * Electrical wires secured * No component
Panacea, FL 32346
Liam S.
Liam S. Checked in
Today, I arrived on site to assess the equipment condition. * Overall equipment condition rated as good. * No immediate issues observed that could affect performance. * All components appear to be functioning within normal parameters. * Routine maintenance checks completed without any findings. * System cleanliness is satisfactory, contributing to optimal operation. * No signs of wear or damage noted during inspection. In Tallahassee FL
Panacea, FL 32346
Liam S.
Liam S. Checked in
Today, I arrived on site to perform a summer time tune-up on the HVAC system. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Location: Attic, Air Handler, Closet * Services: 1st Floor, 2nd Floor * Filtration: Pleated 1" filter, size 20x20, checked today * Indoor Coil: Cleaned with a brush, good condition Outdoor Unit Details: * Location: Side of house, Heat Pump * Outdoor Coil: Cleaned, good condition Electrical Components: * All tested components functioning properly: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring System Inspection: * Components in good condition: * Blower Wheel * Primary Drain Pan * Secondary Drain Pan * Electrical Wires secured * No poor condition components noted. Additional Checks: * Carbon Monoxide test: N/A * Return Air Tempe
Panacea, FL 32346
Joe T.
Joe T. Checked in
Customer said that the minisplit was leaking water. Found that the sink was clogged preventing the tube from draining and the water was coming out of the relief hole from the old condensate pump system that was bypassed due to the pump being bad. Got rid of the part and attached the drain in a better way. Could not check the duct work due to being unable to remove the access panel on the side of the house. We are sending the information to a guy to remove the access panel and add an interior scuttle to the attic. Thank you for your business.
Panacea, FL 32346
Brenden N.
Brenden N. Checked in
Upon arrival, I found the customer’s heat pump zone system not cooling the downstairs properly due to the damper actuator being stuck closed. They were the older style 2wire actuators. I sent the customer an estimate to replace both of them. He approved the estimate. After installing the two new damper actuators, I tested the system operations. Both the downstairs and upstairs were opening and closing properly. Your zone system is operating properly at this time.
Panacea, FL 32346
Aidan D.
Aidan D. Checked in
Today, I arrived on site to perform summer maintenance on the HVAC equipment. Equipment Condition: * Overall equipment condition is good. * Indoor unit located in the attic is an air handler. * Outdoor unit, a heat pump, is situated on the side of the house. Filtration: * Filter types checked today include pleated 1" filters. * Filter sizes noted: 12x12, 20x20, 12x24. Indoor Coil: * Condition is good and clean. Outdoor Coil: * Condition is also good and clean. Electrical Components: * Tested and found to be working properly: blower motor, heat strip kit, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, defrost control board, and electrical wiring. * No components were found not working properly. System Inspection: * Inspected and confirmed good condition: blower wheel, electrical wires secured, primary drain pan, and secondary drain pan. * No components were noted in poor condition. Temperature Readings: * Return air temperature is 69.0°F
Panacea, FL 32346
Liam S.
Liam S. Checked in
Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition: * Overall condition is good. Indoor Unit Details: * Mini split indoor unit located indoors. * Whole home services provided. * Washable filter was washed today. * Condition of indoor coil is good and was brush cleaned today. Outdoor Unit Details: * Mini split condenser located on the side of the house. * Condition of outdoor coil is good and was cleaned today. Electrical Components: * Blower motor, inducer draft motor, heat strip kit, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring tested and are working properly within manufacturer's recommended specs and amperages. System Inspections: * Blower wheel, primary drain pan, secondary drain pan, and electrical wires secured inspected and found in good condition. * No components were found in poor condition. Temperature Readings: * Return air tem
Panacea, FL 32346
Liam S.
Liam S. Checked in
Today, I arrived on site to perform summer maintenance on the HVAC system. Overall Equipment Condition: * Equipment is in good condition. Indoor Unit: * Location: Attic * Type: Air Handler * Services: Whole Home * Filtration: Pleated 1", checked today * Filter Size: 20x20 * Indoor Coil: Good condition, brush cleaned today Outdoor Unit: * Location: Side of House * Type: Heat Pump * Outdoor Coil: Good condition, cleaned today Electrical Components: * All tested electrical components are working properly: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring * No components were found to be malfunctioning. Inspections: * Components in good condition: * Blower Wheel * Primary Drain Pan * Secondary Drain Pan * Electrical Wires secured * No components were reported in poor condition. Testing: * Return Air Temperature: 71.0°
Panacea, FL 32346
Liam S.
Liam S. Checked in
Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted throughout the system. Indoor Unit: * Located in the closet; air handler type. * Services the whole home. * Pleated 1" filter checked today. * Filter size is 16x21; clean condition observed. * Indoor coil is good and was brush cleaned today. Outdoor Unit: * Located on the side of the house; heat pump type. * Outdoor coil is in good condition and was cleaned today. Electrical Components: * Blower Motor, Inducer Draft Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, and Electrical Wiring tested and are working properly within manufacturer specifications. Inspected Components: * Blower Wheel, Primary Drain Pan, Secondary Drain Pan, and Electrical Wires secured; all in good condition. * No components found in poor condition. Temperature Readings: * Return Air Temperature:
Panacea, FL 32346
Brenden N.
Brenden N. Checked in
Today I performed a routine maintenance on your Daikin heat pump split system. I checked all electrical connections on both the indoor and outdoor equipment, flushed your drain line, changed the air filters, checked the capacitor ratings and made sure the system was on and operating properly before I left. Your system is operating properly at this time. I also brought a box of air filters and left the remaining filtersin the laundry room.
Panacea, FL 32346
Brenden N.
Brenden N. Checked in
Today I performed a routine maintenance on your heat pump split system. I checked all electrical connections on both indoor and outdoor equipment, changed your air filter, flushed the drain line, checked the capacitor ratings, and then ran your system to make sure everything was operating properly. Your system is operating properly at this time. .
Panacea, FL 32346
Review
Professional, courteous, knowledgeable.
John - Panacea, FL 32346
Review
Lee is very professional and knowledgeable
DEMONT - Panacea, FL 32346
Review
Awesome young man and a very hard worker. Perfect service.
Mark Duncan - Panacea, FL 32346
Response from Benson's Heating and Air Conditioning:

Thank you so much for taking the time to leave an excellent rating. We really appreciate your business.

Review
Excellent job
DEMONT - Panacea, FL 32346
Response from Benson's Heating and Air Conditioning:

Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.

Review
Very polite and friendly
Bigham - Panacea, FL 32346
Review
Excellent service
DEMONT - Panacea, FL 32346
Review
Hunter provided two PM’s today, was very helpful and professional.
CHRISTIE - Panacea, FL 32346
Review
Hunter was a pleasure to meet, very helpful and professional!
CHRISTIE - Panacea, FL 32346
Review
Showed up early (called and asked). Very efficient and polite
Bigham - Panacea, FL 32346
Review
Quality service
Key - Panacea, FL 32346
Review
Lee and the installation team were knowledgeable, professional, friendly and very helpful.
CHRISTIE - Panacea, FL 32346
Review
Bensons is the best !
Thomas - Panacea, FL 32346
Review
Great customer service!
BOENEKE - Panacea, FL 32346
Review
Very professional
RHODES - Panacea, FL 32346
Response from Benson's Heating and Air Conditioning:

Thanks for sharing your rating with us and the community.

Review
Always great when they find nothing wrong
Thomas - Panacea, FL 32346
Review
Good job great personality
Tucker - Panacea, FL 32346
Review
Very polite and informative
Bigham - Panacea, FL 32346
Review
Great service
DEMONT - Panacea, FL 32346
Review
Professional, efficient, courteous serves
BAILEY - Panacea, FL 32346
Review
Great service
DEMONT - Panacea, FL 32346
Review
Always a great experience
WOOD - Panacea, FL 32346
Review
Great job
TURNER - Panacea, FL 32346
Review
Always great service.
RUDD - Panacea, FL 32346
Review
He was excellent
MANGUM - Panacea, FL 32346
Review
Always great
Thomas - Panacea, FL 32346

It’s Even Better With The App! Download Now:

Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request
*
Your Contact and Service Location
*
*
To Serve You Best
Have we served you in the past?
Yes
No
What Date Would You Like To Schedule Your Service?
What time of day is best for you?
First Available
Morning
Afternoon
By pressing Submit I agree to receive phone, email, or text messages from Benson's Heating and Air Conditioning to the provided mobile number and also agree to the Benson's Heating and Air Conditioning terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next